Liebert VERTIV (GXT5LI8000GVRT3UXLN) Algemeen Doel UPS (GXT5LI-8000GVRT3UXLN)
Liebert VERTIV (GXT5LI8000GVRT3UXLN) Algemeen Doel UPS (GXT5LI-8000GVRT3UXLN)
Liebert GXT5LI-8000GVRT3UXLN
- Free Shipping
- 5 Year Garantie
- 30 dagen retourneren
- Klimaatneutraal
uren
minuten
Verzendinformatie
Liebert VERTIV (GXT5LI8000GVRT3UXLN) Algemeen Doel UPS (GXT5LI-8000GVRT3UXLN)
Liebert GXT5LI-8000GVRT3UXLN
- Free Shipping
- 5 Year Garantie
- 30 dagen retourneren
- Klimaatneutraal
uren
minuten
Verzendinformatie
Liebert
GXT5LI-8000GVRT3UXLN
GXT5LI-5KL630RT3UXLN
Maximum Power (VA/W): 5000VA/4900W
Maximum Output Power Factor: 0.98
Full-Load Runtime: 11 min
Half-Load Runtime: 25 min
Remote Management Capabilities:
Included with RDU101 SNMP/Webcard and FREE Vertiv Power Insight management software for remote monitoring / management (web based, SNMP, BACnet, MODBUS and relay contacts)
Recharge Time (from full discharge): < 2hrs to 90%
Unit Weight Lbs. (Kgs) (w/o EBCs): 103(47)
Warranty: 5 years on UPS and Battery
Form Factor: 3U Rack/Tower
Output: Hardwired (L1-L2-G)
GXT5LI-6000GVRT3UXLN
Maximum Power (VA/W): 6000VA/6000W
Maximum Output Power Factor: 1.0
Full-Load Runtime: 9 min
Half-Load Runtime: 19 min
Remote Management Capabilities:
Included with RDU101 SNMP/Webcard and FREE Vertiv Power Insight management software for remote monitoring / management (web based, SNMP, BACnet, MODBUS and relay contacts)
Recharge Time (from full discharge): < 2hrs to 90%
Unit Weight Lbs. (Kgs) (w/o EBCs): 99(45)
Warranty: 5 years on UPS and Battery
Form Factor: 3U Rack/Tower
Output: Hardwired (L1-L2-G)
GXT5LI-8000GVRT3UXLN
Maximum Power (VA/W): 8000VA/8000W
Maximum Output Power Factor: 1.0
Full-Load Runtime: 5 min
Half-Load Runtime: 15 min
Remote Management Capabilities:
Included with RDU101 SNMP/Webcard and FREE Vertiv Power Insight management software for remote monitoring / management (web based, SNMP, BACnet, MODBUS and relay contacts)
Recharge Time (from full discharge): < 2hrs to 90%
Unit Weight Lbs. (Kgs) (w/o EBCs): 105(48)
Warranty: 5 years on UPS and Battery
Form Factor: 3U Rack/Tower
Output: Hardwired (L1-L2-G)
GXT5LI-10KGVRT3UXLN
Maximum Power (VA/W): 10000VA/10000W
Maximum Output Power Factor: 1.0
Full-Load Runtime: 4 min
Half-Load Runtime: 11 min
Remote Management Capabilities:
Included with RDU101 SNMP/Webcard and FREE Vertiv Power Insight management software for remote monitoring / management (web based, SNMP, BACnet, MODBUS and relay contacts)
Recharge Time (from full discharge): < 2hrs to 90%
Unit Weight Lbs. (Kgs) (w/o EBCs): 105(48)
Warranty: 5 years on UPS and Battery
Form Factor: 3U Rack/Tower
Output: Hardwired (L1-L2-G)
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |