Tripp Lite SU3000RTXLCD2UN SmartOnline 3000VA Rack-mountable UPS Pure Sine Wave 9 Outlet 트립 라이트 SU3000RTXLCD2UN SmartOnline 3000VA 랙 마운터블 UPS 순진파 9 아웃렛

Front view of Tripp Lite SmartOnline UPS showing LCD display panel and ventilation grilles-alternate-image1
Side angle view of Tripp Lite SmartOnline UPS showing 2U rack mount design-alternate-image2
Angled view of Tripp Lite SmartOnline UPS emphasizing pure sine wave technology-alternate-image3
Rear view of Tripp Lite SmartOnline UPS showing ports, outlets, and cooling system-alternate-image4
Tower configuration of Tripp Lite SmartOnline UPS with LCD display and mounting base-alternate-image5

Tripp Lite SU3000RTXLCD2UN SmartOnline 3000VA Rack-mountable UPS Pure Sine Wave 9 Outlet 트립 라이트 SU3000RTXLCD2UN SmartOnline 3000VA 랙 마운터블 UPS 순진파 9 아웃렛

Tripp Lite SU3000RTXLCD2UN

RM11,678.00 MYR RM20,963.00 MYR Save RM9,285 MYR
Authorized Partner
Brand New
Availability: In stock , ready to be shipped .
  • Free Shipping
  • 1 Year Warranty
  • 30 Day Returns
  • Carbon Neutral

Product Key Features

  • 전원 고장 및 전압 변동에 대한 네트워크급 보호를 제공합니다
  • 온라인 및 배터리 모드 간 전환 시간이 없어 연속적인 작동이 가능합니다
  • 필요한 애플리케이션을 위해 추가 운영 시간을 제공하는 선택적 외장 배터리 팩
  • 포함된 WEBCARDLX 네트워크 인터페이스를 통해 어디서든 24/7 원격 액세스 가능
  • 선택적 에코노미 모드로 전기 사용량을 줄이고 에너지 비용을 절감하세요}
RM11,678.00 MYR
FREE Returns
FREE Delivery
다음에 주문하세요

hrs

mins

배달 예정일:

배송 정보

-
+
Ask Our Experts
Call Us Now
888.267.9566
Minimize
Info
Info Page
Reviews Top
×

×
  • 설명하다
  • 기술 사양
  • 환불 정책

Tripp Lite

SU3000RTXLCD2UN

Tripp Lite SmartOnline 3000VA Double-Conversion Rack-Mount UPS with Pure Sine Wave Output

The Tripp Lite SU3000RTXLCD2UN SmartOnline UPS delivers premium power protection with double-conversion technology and pure sine wave output for mission-critical equipment in data centers, healthcare facilities, and enterprise environments. This 3000VA/2700W rack-mountable UPS system features zero transfer time, advanced surge protection, and comprehensive remote management capabilities.

Advanced Power Protection Features

  • True double-conversion online operation with zero transfer time
  • Pure sine wave output with 3000VA/2700W capacity
  • 570 joules surge protection and EMI/RFI noise filtering
  • Input voltage range: 100-127V AC with 60Hz frequency
  • Nine total outlets: 1x L5-30R, 4x 5-15/20R, 4x 5-15R

Intelligent Battery Management & Runtime

  • Hot-swappable VRLA battery modules for continuous operation
  • 4.1 minutes runtime at full load, 11.3 minutes at half load
  • Expandable runtime with up to four BP72RT battery modules
  • 72V DC system voltage with replaceable batteries
  • LCD interface displays battery status and power analytics

Network Management & Communication

  • Pre-installed WEBCARDLXE for SNMP/HTTP remote monitoring
  • RS-232, USB, and dry-contact relay ports
  • RPO/ROO port for emergency shutdown and remote restart
  • Compatible with EnviroSense2 environmental monitoring
  • Comprehensive alarm system including power failure and overload alerts

Package Contents

  • SmartOnline SU3000RTXLCD2UN 3000VA Rack-mountable UPS
  • WEBCARDLX Network Interface Card
  • USB Cable
  • RS-232 Cable
  • EPO Cable
  • 4-post Rack-mounting Hardware
  • Owner's Manual
더블 컨버전션 UPS는 장비를 손상, 다운타임 및 데이터 손실로부터 보호합니다

이 온라인 더블 컨버전션 UPS 시스템은 AC 입력을 DC로 변환한 다음 UPS 출력을 완전히 규제된 사인파 AC로 다시 변환하여 완벽한 출력을 유지합니다. 지속적인 온라인 작동은 AC 라인의 모든 전력 문제로부터 민감한 장비를 완전히 격리합니다. SmartOnline® SU3000RTXLCD2UN은 공간이 제한되지만 프리미엄 전력 신뢰성이 꼭 필요한 교육, 보건의료, 군사, 정부 및 기타 미션 크리티컬 IT 응용 프로그램을 위한 최고 수준의 전원 보호 및 배터리 백업을 제공합니다.

신뢰할 수 있는, 확장 가능한 배터리 백업으로 전원 장애에 대비

교체 가능한 핫-스왑 가능한 VRLA 배터리 모듈은 단기간의 전력 장애를 통해 작업할 수 있으며, 장시간의 블랙아웃의 경우 파일을 안전하게 저장하고 시스템을 종료할 충분한 시간을 제공합니다. 온라인과 배터리 모드 간의 이동 시간이 없어 연결된 장비의 연속적인 운영을 중단이나 재부팅 없이 유지합니다. 옵션의 추가 배터리 모듈 (BP72RT, 별도 판매)을 최대 4개 연결하여 추가 실행 시간을 늘릴 수 있습니다.

사전 설치된 LX 플랫폼 네트워크 관리 카드가 24/7 원격 액세스를 제공합니다

WEBCARDLXE 네트워크 인터페이스를 통해 전체 원격 구성 및 관리가 가능하며, 로드 셰딩, 연결된 장비의 재부팅 및 안전한 종료를 포함합니다. IP 기반의 Auto Probe 기능으로 다른 네트워크 장치와 통신하여 연속적인 네트워크 가동 시간을 보장하고 연결이 끊긴 경우를 감지하고 IT 장비를 자동으로 재부팅합니다. 옵션의 EnviroSense2 모듈 (E2MT, E2MTDO 및 E2MTHDI, 모두 별도 판매)은 다양한 환경 모니터링 및 제어 옵션을 제공합니다.

NEMA 콘센트가 연결된 구성 요소를 보호합니다

L5-30R 및 5-20R 스펙의 콘센트는 연결된 장비에 순수 사인파 AC 출력을 제공하고 전력 소비량을 콘센트 그룹 수준까지 모니터링할 수 있습니다. 이러한 콘센트에서 제공하는 전력은 연결된 장비를 손상시키는 과전압과 라인 노이즈로부터 보호됩니다. 5-20R 콘센트 중 4개는 비상 상황을 위해 비상 상황을 위해 비상 상황을 켜기위한 로드 뱅크로 그룹화되어 임계적인 부하를 위한 실행 시간을 연장할 수 있습니다.

EMI/RFI 라인 노이즈로부터의 프리미엄 보호로 장비의 성능을 높입니다

이 UPS 시스템은 하드웨어 손상이나 데이터 손실을 초래할 수 있는 방해 전자기 및 라디오 주파수 간섭을 제거합니다. 이 EMI/RFI 필터링은 연결된 구성 요소의 성능을 향상시키고 오래 사용할 수 있도록 돕습니다.

명료한 LCD 인터페이스는 한눈에 정보를 제공합니다

메뉴 기반의 전면 패널 LCD는 문제를 진단하는 데 도움이 되는 자세한 경보 및 알림을 제공합니다. 시스템 상태, 이벤트 로그, 배터리 및 전원 모듈 상태, 사용 분석, 일련 번호, 펌웨어 업데이트 정보 등을 제공합니다. UPS가 배터리 전원으로 전환되었을 때 알림음을 전면 메뉴를 통해 비활성화할 수 있습니다. LCD는 랙 마운트 및 타워 설치를 모두 수용할 수 있도록 회전합니다.

고급 통신 포트를 통해 자동 저장 및 종료가 가능합니다

RS-232 및 USB 포트는 다양한 통신 옵션을 위해 장치에 연결됩니다 (케이블이 포함되어 있음). 건조 접촉 릴레이 포트는 LCD를 통해 프로그래밍하여 자동화 및 산업 구성 요소에 안정적인 통신을 제공할 수 있습니다. RPO/ROO 포트를 사용하여 모든 연결된 장비의 비상 종료 또는 원격 재시작이 가능합니다.

Return Policy

Time to Return

Standard Return Policy

We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.

Replacement Only Return Policy

Replacement within 30 days of the delivery date.

Manufacturer Only Return Policy

Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.

Holiday Extended Return Policies

Extended Holiday Return Policy.

Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024.


Extended Holiday Replacement-Only Return Policy

Qualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.

Front view of Tripp Lite SmartOnline UPS showing LCD display panel and ventilation grilles

Intelligent LCD Interface for Real-Time Power Management

The front panel features an advanced LCD display that provides critical power status information at a glance. The intuitive menu-driven interface allows easy access to system parameters, operating mode, and real-time power conditions. Complemented by ventilation grilles on both sides, this design ensures optimal thermal management while delivering comprehensive monitoring capabilities.

Technical Specifications

  • Menu-driven LCD interface for system monitoring
  • Real-time status display of voltage and frequency
  • Dual ventilation grilles for enhanced cooling

Applications

  • Data center power monitoring
  • IT infrastructure management
  • Mission-critical system oversight
Side angle view of Tripp Lite SmartOnline UPS showing 2U rack mount design

2U Rack-Optimized Design with Advanced Cooling

The 2U rack-mount form factor maximizes space efficiency in server rooms and data centers. The robust chassis features strategically placed ventilation systems that maintain optimal operating temperatures. The LCD interface provides instant access to critical parameters while maintaining the unit's compact profile.

Technical Specifications

  • 2U rack-mount form factor
  • Integrated thermal management system
  • Space-efficient chassis design

Applications

  • Server rack integration
  • Network closet installation
  • Data center deployment
Angled view of Tripp Lite SmartOnline UPS emphasizing pure sine wave technology

Pure Sine Wave Output with Continuous Power Conditioning

This UPS delivers clean, continuous power through its double-conversion architecture. The system maintains perfect output by converting AC to DC and back to AC, ensuring connected equipment receives pristine power free from irregularities and distortions.

Technical Specifications

  • Double-conversion technology
  • Pure sine wave output
  • Zero transfer time to battery

Applications

  • Sensitive equipment protection
  • Laboratory instrument power
  • Medical equipment backup
Rear view of Tripp Lite SmartOnline UPS showing ports, outlets, and cooling system

Comprehensive Connectivity and Power Distribution

The rear panel showcases extensive connectivity options including USB, network, and serial ports for comprehensive system integration. Multiple outlet groups enable strategic load management, while the cooling fan and communication ports ensure reliable operation and remote monitoring capabilities.

Technical Specifications

  • Multiple communication interfaces
  • Grouped outlet configuration
  • Active cooling system

Applications

  • Remote power management
  • Network integration
  • Critical load distribution
Tower configuration of Tripp Lite SmartOnline UPS with LCD display and mounting base

Flexible Tower Configuration with Active Monitoring

The vertical tower orientation offers alternative mounting options for environments where rack space is limited. The rotatable LCD display maintains easy readability in tower position, while the sturdy base ensures stable deployment. The comprehensive ventilation system continues to provide efficient cooling in this orientation.

Technical Specifications

  • Convertible rack/tower design
  • Rotatable display interface
  • Stable mounting system

Applications

  • Office power protection
  • Space-constrained installations
  • Standing deployment scenarios
FAQ
The Tripp Lite SU3000RTXLCD2UN UPS has a load capacity of 3000VA/2700W. It operates on 120V AC input with a range of 100-127V AC, providing pure sine wave output at 120V AC (adjustable to 100V, 110V, 115V, or 127V AC). This capacity makes it suitable for protecting servers, computers, and other mission-critical equipment in data centers.
The UPS system features 9 outlets total: 1 NEMA L5-30R outlet, 4 NEMA 5-15/20R outlets, and 4 NEMA 5-15R outlets. The outlets are organized into load banks, allowing you to shed non-critical loads to extend runtime for critical equipment. All outlets provide pure sine wave AC output with surge protection and EMI/RFI filtering.
The UPS provides 4.10 minutes of runtime at full load and 11.30 minutes at half load. For extended runtime, you can connect up to four optional BP72RT battery modules (sold separately). The system features hot-swappable, field-replaceable VRLA battery modules, allowing for continuous operation during battery replacement.
The UPS includes a pre-installed WEBCARDLXE network interface for remote management, SNMP/HTTP monitoring, and configuration. It features a menu-driven LCD display showing system status, event logs, battery status, and analytics. The system also includes RS-232 and USB ports, a dry-contact relay port, and RPO/ROO ports for emergency shutdown. Multiple alarm types include power failure, low battery, overload, and UPS fault notifications.
The SU3000RTXLCD2UN is a 2U rack-mountable UPS measuring 3.4" H x 17.3" W x 25.5" D and weighing 70.50 lbs. It can be installed in both rack-mount and tower orientations, with the LCD screen rotating to accommodate either position. The package includes 4-post rack-mounting hardware for installation.
This UPS provides comprehensive protection including double-conversion online operation with zero transfer time, 570 joules of surge protection, and EMI/RFI noise filtering. It maintains perfect output by converting AC to DC and back to pure sine wave AC, completely isolating connected equipment from power problems. The system includes a $250,000 lifetime connected equipment guarantee.
The UPS operates at temperatures up to 104°F (40°C) and can be stored between 5°F (-15°C) and 122°F (50°C). It can function at elevations up to 9,842.52 feet, with a noise level of 50 dB(A). The unit has a thermal dissipation of 476.53W and operates in relative humidity of 0-95% non-condensing. It's environmentally friendly and RoHS certified.
The Tripp Lite SU3000RTXLCD2UN comes with a 2-year limited warranty and a $250,000 lifetime connected equipment guarantee. The package includes comprehensive documentation, USB cable, RS-232 cable, EPO cable, and the pre-installed WEBCARDLX Network Interface Card for technical support and remote management capabilities.

Related searches

액세서리

Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart

비슷한 제품

Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart

Recently Viewed Products

Compare Details Tripp Lite SU3000RTXLCD2UN SmartOnline 3000VA Rack-mountable UPS Pure Sine Wave 9 Outlet 트립 라이트 SU3000RTXLCD2UN SmartOnline 3000VA 랙 마운터블 UPS 순진파 9 아웃렛

Tripp Lite by Eaton SmartOnline 3kVA On-Line Double-Conversion UPS, 3U Rackmount, Interactive LCD display, 100/110/120/127V NEMA outlets (SU3000RTXLCD3U)

Tripp Lite by Eaton SmartOnline 3kVA On-Line Double-Conversion UPS, 3U Rackmount, Interactive LCD display, 100/110/120/127V NEMA outlets (SU3000RTXLCD3U)

Tripp Lite SU3000RTXLCD2U SmartOnline 3000VA 타워/랙 마운트 가능 UPS 순정 사인파 4.10분 백업 SNMP 관리 가능

Tripp Lite SU3000RTXLCD2U SmartOnline 3000VA 타워/랙 마운트 가능 UPS 순정 사인파 4.10분 백업 SNMP 관리 가능

APC: APC Smart-UPS: 스마트-UPS SRT: SRT 3000VA: 3000VA RM: RM 208V: 208V SRT3000RMXLT: SRT3000RMXLT

APC: APC Smart-UPS: 스마트-UPS SRT: SRT 3000VA: 3000VA RM: RM 208V: 208V SRT3000RMXLT: SRT3000RMXLT

APC SRT3000RMXLT Smart-UPS SRT 3000VA RM 208V Double Conversion Online UPS 3000 VA/2700 W 208 V AC  APC SRT3000RMXLT Smart-UPS SRT 3000VA RM 208V 이중 변환 온라인 UPS 3000 VA/2700 W 208 V AC

APC SRT3000RMXLT Smart-UPS SRT 3000VA RM 208V Double Conversion Online UPS 3000 VA/2700 W 208 V AC APC SRT3000RMXLT Smart-UPS SRT 3000VA RM 208V 이중 변환 온라인 UPS 3000 VA/2700 W 208 V AC