Tripp Lite PDUMNH32HVAT PDU 7.4kW Monofase 230V ATS/Monitored PDU
Tripp Lite PDUMNH32HVAT PDU 7.4kW Monofase 230V ATS/Monitored PDU
Tripp Lite PDUMNH32HVAT
- Free Shipping
- 1 Anno Garanzia
- Resi entro 30 giorni
- Carbon Neutral: Neutro in carbonio
Caratteristiche chiave del prodotto
- Due ingressi blu IEC 309 32A (2P+E) con cavi da 10 ft. (3 m)
- Presa blu IEC 309 32A (2P+E) per collegare dispositivi o PDU a 0U
- Commutazione automatica entro 1-5 ms
- Interfaccia di rete Ethernet per l'accesso remoto
- Display digitale con LED per il monitoraggio dello stato in tempo reale}
ore
minuti
Informazioni di spedizione
Tripp Lite PDUMNH32HVAT PDU 7.4kW Monofase 230V ATS/Monitored PDU
Tripp Lite PDUMNH32HVAT
- Free Shipping
- 1 Anno Garanzia
- Resi entro 30 giorni
- Carbon Neutral: Neutro in carbonio
ore
minuti
Informazioni di spedizione
Caratteristiche chiave del prodotto
- Due ingressi blu IEC 309 32A (2P+E) con cavi da 10 ft. (3 m)
- Presa blu IEC 309 32A (2P+E) per collegare dispositivi o PDU a 0U
- Commutazione automatica entro 1-5 ms
- Interfaccia di rete Ethernet per l'accesso remoto
- Display digitale con LED per il monitoraggio dello stato in tempo reale}
Tripp Lite
PDUMNH32HVAT
I cavi di ingresso duali da 3 metri (10 piedi), ciascuno con spina di ingresso blu IEC 309 32A, si collegano a due sorgenti di alimentazione primarie e secondarie separate, comprese le sorgenti di ingresso fuori fase. La PDU valuta costantemente la qualità dell'alimentazione di entrambi gli ingressi. Per garantire che l'attrezzatura collegata resti alimentata, il commutatore automatico a stato solido dinamico (TRIAC) consente alla PDU di passare alla sorgente secondaria entro 1-5 millisecondi se la sorgente primaria fallisce o diventa instabile.
L'interfaccia di gestione di rete integrata LX Platform consente l'accesso remoto alla PDU per il monitoraggio dell'alimentazione, la configurazione, il controllo e la ricezione di notifiche configurabili dall'utente. L'interfaccia di rete basata su HTML5 di LX Platform senza Java consente un completo accesso remoto per il monitoraggio dello stato della PDU e le notifiche via email tramite browser web sicuro, SNMP, telnet o SSH. Fornisce dati sul carico/corrente in tempo reale con precisione del conteggio delle bollette (+/- 1 percento). Supporta auto-detection 10/100 Mbps per una comunicazione ottimale con una rete Ethernet. I moduli opzionali EnviroSense2 (venduti separatamente) forniscono una varietà di funzionalità di monitoraggio ambientale. I protocolli supportati includono HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP e NTP.
ATS PDU Distributes and Monitors Single-Phase Power with No Java Required
Featuring a built-in network interface and an auto transfer switch, Tripp Lite's PDUMNH32HVAT 7.4kW Single-Phase Monitored ATS PDU provides full remote power monitoring and a redundant power option for network devices with non-redundant power supply configurations. Dual inputs allow connection to separate primary and secondary power sources for solid-state automatic transfer switching to keep equipment running without interruption. Connect its Blue IEC-309 32A (2P+E) receptacle to a single device or a 230V PDU (sold separately) to power additional outlets.
Product Specifications
Dual PDU Inputs Provide Power Redundancy for Network DevicesThe PDUMNH32HVAT has two 10 ft. input cords with Blue IEC-309 32A plugs to support connection to separate primary and secondary single-phase power sources, such as separate mains circuits, backup generators and even separate utility power grid feeds. The two power sources provide power redundancy for network devices with non-redundant power supply configurations. The dual power sources enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (primary UPS should produce a sine wave with zero transfer time). The PDUMNH32HVAT has a rugged all-metal housing and provides 230V output. Maximum input current is 32A. |
|
Auto Transfer Switch (ATS) Provides Reliable, Continuous OutputDynamic solid-state (TRIAC) automatic transfer switching is supported by any two compatible AC power sources. The PDUMNH32HVAT supplies continuous output to its IEC-309 receptacle from the primary power source. If the primary source fails or becomes unstable, the ATS switches to the secondary power source until the primary source is restored. An on-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when it’s unavailable or of lower quality than the primary source. The transfer between power sources happens in 1 to 5 milliseconds, ensuring uninterrupted operation of connected equipment. |
|
HTML5-Based Interface Provides Advanced Network Monitoring CapabilitiesWith a built-in Java-free, HTML5-based LX Platform interface (the mobile-friendly PowerAlert Device Manager), the PDUMNH32HVAT provides complete remote access for power monitoring and email notifications via a secure network or Web browser. When used with an optional EnviroSense2 environmental sensor (sold separately), it can also perform temperature/humidity and dry contact monitoring, providing IT personnel with enhanced oversight of facility power and environmental conditions. As an added bonus, up to three EnviroSense2 modules can be daisy-chained together. The PDUMNH32HVAT supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts can be configured to warn against potential overload, power loss and downtime. |
|
Supports Real-Time Load and Power Status MonitoringThe PDUMNH32HVAT is equipped with a digital ammeter that allows you to monitor the PDU’s total load in real time. This meter helps ensure the PDU is used below maximum capacity with no danger of overload. Reduces the Cost of Data Center Maintenance Remote monitoring capabilities lower the PDUMNH32HVAT’s total cost of ownership by reducing the frequency of on-site visits. Integrates Easily Into Your Existing Infrastructure The PDUMNH32HVAT mounts horizontally in any EIA-standard 19 in. rack. It occupies just 1U of space. For extra support, a PDU4PKIT Rear Support Rail Kit is included. |
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is a leading manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosures, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 90 years of quality products and service, Tripp Lite is a brand you can trust.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |