Tripp Lite PDUMNV32HV2LX 42-Outlet PDU Monitored 7.4KW Single-Phase 32A Input 230V AC Rack-mountable Tripp Lite PDUMNV32HV2LX 42-Uscita PDU Monitorato 7.4KW Monofase 32A Ingresso 230V AC Rack-montabile
Tripp Lite PDUMNV32HV2LX 42-Outlet PDU Monitored 7.4KW Single-Phase 32A Input 230V AC Rack-mountable Tripp Lite PDUMNV32HV2LX 42-Uscita PDU Monitorato 7.4KW Monofase 32A Ingresso 230V AC Rack-montabile
Tripp Lite PDUMNV32HV2LX
- Free Shipping
- 1 Anno Garanzia
- Resi entro 30 giorni
- Carbon Neutral: Neutro in carbonio
ore
minuti
Informazioni di spedizione
Tripp Lite PDUMNV32HV2LX 42-Outlet PDU Monitored 7.4KW Single-Phase 32A Input 230V AC Rack-mountable Tripp Lite PDUMNV32HV2LX 42-Uscita PDU Monitorato 7.4KW Monofase 32A Ingresso 230V AC Rack-montabile
Tripp Lite PDUMNV32HV2LX
- Free Shipping
- 1 Anno Garanzia
- Resi entro 30 giorni
- Carbon Neutral: Neutro in carbonio
ore
minuti
Informazioni di spedizione
Tripp Lite
PDUMNV32HV2LX
Il PDU 0U dispone di 42 prese (36 C13 e 6 C19) con inserti a scatto per evitare che i cavi si scollegano accidentalmente. Un cavo da 10 piedi con spina IEC 309 32A Blu (2P+E) collega il PDU a una sorgente di alimentazione AC compatibile, a un generatore o a un UPS protetto.
L'interfaccia di rete LX Platform integrata, basata su HTML5 senza Java, consente un accesso remoto completo per il monitoraggio dello stato del PDU e le notifiche via e-mail tramite browser web sicuro, SNMP, telnet o SSH. Supporta la velocità automatica 10/100 Mbps per una comunicazione ottimale con una rete Ethernet. I moduli opzionali EnviroSense2 (venduti separatamente) offrono una varietà di funzionalità di monitoraggio ambientale. I protocolli supportati includono IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP e NTP.
Un amperometro digitale ti permette di monitorare la corrente di ciascun banco di carico e il carico PDU complessivo collegato in tempo reale per garantire che rimangano ben al di sotto della capacità massima senza pericolo di sovraccarico. Il PDU si monta in 0U di spazio in rack standard EIA da 19 pollici utilizzando i pulsanti di montaggio senza attrezzi inclusi o le staffe di montaggio rack incluse. Utilizza il kit PDUMVROTATEBRKT incluso per installare l'unità con le prese rivolte verso la parte posteriore per una migliore circolazione dell'aria o accesso all'attrezzatura.
Next-Generation PDU Distributes and Monitors Single-Phase Power with No Java Required
Featuring a built-in network interface, Tripp Lite's PDUMNV32HV2LX 7.4kW Single-Phase Monitored PDU provides full remote power monitoring for network devices in server rooms, network closets and small data centers. Its 42 outlets (36 C13 and 6 C19) are split into two separately breakered 20A banks, which can each be monitored both locally and remotely. Designed for users who prefer a Java-free interface, this advanced vertical PDU distributes 230V output and is recommended for any IT or industrial application. Its 10 ft. cord with IEC 309 32A Blue plug connects to a compatible power source, generator or UPS.
Key Features
HTML5-Based Interface Provides Advanced Network Monitoring Capabilities
With a built-in Java-free, HTML5-based LX Platform interface (the mobile-friendly PowerAlert Device Manager), the PDUMNV32HV2LX provides complete remote access for power monitoring and email notifications via a secure network or Web browser. When used with an optional EnviroSense2 environmental sensor (sold separately), it can also perform temperature/humidity and dry contact monitoring, providing IT personnel with enhanced oversight of facility power and environmental conditions. As an added bonus, up to three EnviroSense2 modules can be daisy-chained together. The PDUMNV32HV2LX supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts can be configured to warn against potential overload, power loss and downtime.
Supports Real-Time Load and Power Status MonitoringThe PDUMNV32HV2LX is equipped with a digital ammeter that allows you to monitor each of its two outlet banks as well as the PDU’s total load in real time. This meter helps ensure the PDU is used below maximum capacity with no danger of overload. Reduces the Cost of Data Center Maintenance Advanced remote monitoring capabilities lower the PDUMNV32HV2LX’s total cost of ownership by reducing the frequency of on-site visits. |
|
Integrates Easily Into Your Existing InfrastructureThis 0U PDU mounts vertically in EIA-standard 19 in. 2-post and 4-post racks using the included toolless mounting buttons or rack-mounting brackets. Using the included PDUMVROTATEBRKT mounting accessory, you can install it with outlets facing either the front or rear, whichever direction offers better airflow or equipment access. Once the PDU is installed in your rack, included plug-lock insert sleeves prevent cables from becoming accidentally disconnected from their outlets. |
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is one of the leading manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosures, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 95 years of quality products and service, Tripp Lite is a brand you can trust.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |