CyberPower Älykäs Sovellus Siniaalivarmennettu UPS PR2000RTXL2UTAA TAA-noudattavat UPS-järjestelmät 2000 VA 8 Pistorasiaa Teline/Torni 2U
CyberPower Älykäs Sovellus Siniaalivarmennettu UPS PR2000RTXL2UTAA TAA-noudattavat UPS-järjestelmät 2000 VA 8 Pistorasiaa Teline/Torni 2U
CyberPower PR2000RTXL2UTAA
- Free Shipping
- 1 vuosi Takuu
- 30 päivän palautusoikeus
- Hiilidioksidineutraali
Tuotteen pääominaisuudet
- Kapasiteetti: 2000 VA / 2000 W
- Topologia: Line Interactive
- Aaltomuoto: Sinimuotoa
- Ulostulo: 100-125 VAC ± 5%
- Pistoketyyppi ja johto: NEMA 5-20P, 10 jalan johto
- Pistoketyypit: 8 × NEMA 5-20R
- Viestintä: USB, Sarja, SNMP, Relaistoiminto, EPO
- Hallintaohjelmisto: PowerPanel® Business
- Etähallinta: Kyllä, valinnaisella RMCARD205TAA:lla
- Takuu: 3 vuotta
tunnit
minuuttia
Toimitustiedot
CyberPower
PR2000RTXL2UTAA
PR2000RTXL2UTAA on älykäs App Sinewave -rack/tower-muunneltava UPS, jossa on line-interactive -topologia, ylijännitesuojaus ja akkuvaraus. CyberPowerin Smart App Sinewave -sarjassa on sinimuotoisen aallon lähtö, joka poistaa virhetilat, joita herkät laitteet voivat havaita ja jotka voivat aiheuttaa odottamattomia sammutuksia.
Smart App Sinewave PR2000RTXL2UTAA parantaa akun käyttöikää akun tasapainotusteknologian ja automaattisen jännitevakauden (AVR) avulla, joka korjaa pieniä tehovaihteluita ilman, että siirrytään akkukäyttöön. Innovatiivinen runkoyhdistelmä helppokäyttöisellä työkaluttomalla etupaneelilla, kiinnitetyt ruuvit akun paneelin pääsyyn ja värikoodattu takapaneeli tekevät akkujen vaihdosta ja asennuksesta yksinkertaista ja nopeaa. PR2000RTXL2UTAA:ssa on myös innovatiivinen LCD-paneeli, joka kääntyy 90°, kallistuu paremman katselukulman saavuttamiseksi ja tarjoaa tietoja 47 eri asetuksesta, mukaan lukien UPS-tilastot, UPS-asetukset ja hallinta sekä testausvaihtoehdot.
Tämä malli hyväksyy BP48VP2U02TAA -pidennetyn akkumoduulin (EBM) virran laajentamiseksi sähkökatkojen aikana ja RMCARD205TAA -verkon hallintakortin etäohjausta ja -valvontaa varten tavallisen verkkoselaimen tai verkonhallintajärjestelmän kautta.
400 000 dollarin liitetyn laitteiston takuu ja kolmen vuoden takuu osoittavat CyberPowerin sitoutumisen PR2000RTXL2UTAA:n laatuun.
PR2000RTXL2UTAA | TAA UPS Systems
Federal Trade Agreements Act (TAA) compliant power protection
The PR2000RTXL2UTAA is a Smart App Sinewave rack/tower convertible UPS with line-interactive topology, surge protection, and battery backup. CyberPower’s Smart App Sinewave series has sine wave output to eliminate power gaps that can be detected by sensitive equipment and cause unexpected shutdowns.
The Smart App Sinewave PR2000RTXL2UTAA improves battery life through battery equalization technology and Automatic Voltage Regulation (AVR), which corrects minor power fluctuations without switching to battery power. The enhanced chassis design with an easy-to-access toolless front panel, captive screws for battery panel access, and color-coded rear panel make battery changes and installations simple and fast. The PR2000RTXL2UTAA also has an innovative LCD panel that rotates 90°, tilts for a better viewing angle, and provides information on 47 different settings including UPS stats, UPS setup and control management, and testing options.
Typical Applications
- Department Servers
- Network Devices
- Corporate Servers
- Storage Devices
- VoIP Installations
- Telecom Installations
Higher Capacity UPS for Longer Runtimes
To determine the size of the UPS that you need, identify the total power load (measure in VA/Watts) of the connected equipment, along with the amount of runtime required (in minutes). Also, think about any equipment that might be connected to the UPS in the future, which could affect the calculations for load and runtime.
Estimating expected UPS runtimes can be challenging, particularly when the consistency of the utility power is not well known. Selecting a UPS with a load capacity 30-35% above the required power load offers the advantage of longer runtimes. This can lower the risk of overloading the UPS and causing an unnecessary UPS shutdown.
Although the initial outlay of a UPS increases with its size because of the higher capacity required for components, long-term operating costs typically decrease. When a UPS operates below maximum capacity, it reduces the stress on components. Sizing a UPS to run loads significantly lower than its capacity also increases spare capacity for future growth, along with extending runtimes.
Efficient Remote Management
The Smart App Series offers full-featured network UPS management capabilities with the PowerPanel® Business Edition software and an optional SNMP network management card. These remote management tools enable centralized power management, monitoring, control, and configuration. They also provide for safe shutdown of connected servers, workstations, and other devices via a standard Web browser or network management system (NMS).
Safe Shutdown
The PowerPanel® Business Edition software, included with every Smart App Sinewave UPS, enables an administrator to remotely manage each aspect of the UPS and facilitate the orderly automatic shutdown of connected equipment in the event of an extended power outage. This software also provides comprehensive network power management for corporate servers and critical workstations supported by the UPS, such as application/operating system shutdown, event logging, reporting, alerts and notifications.
Programmable Outlet Control
Smart App UPS systems allow programming of critical outlets and non-critical outlets, giving administrators the ability to prioritize outlets and increase battery backup runtimes for the most critical equipment during extended power outages. Programmable outlet control also gives an administrator the option to delay-start non-critical outlets, permitting the internal batteries to fully recharge more quickly. This feature is vital to data centers where seamless, uninterrupted equipment bootup is a necessity.
GreenPower UPS Technology: Bypass Design
GreenPower UPS™ Technology from CyberPower improves operating efficiency, reduce heat generation, and consume less power than conventional UPS models.
Our patented Bypass Design allows current to bypass the transformer and automatic voltage regulation (AVR) when utility power is normal, thus reducing energy consumption and associated costs. Because utility power functions normally most of the time, the bypass design allows for substantial energy savings. This technology also reduces heat generation, an important factor in decreasing operating costs.
Sine Wave Power
In the U.S., utility companies provide power to households and offices by distributing single phase alternating current (AC) power at a frequency of 60 Hz. Electrical power can be graphically depicted as a sine wave whereby the electrical signal alternates from +120 volts to -120 volts at a rate of 60 times per second (60 Hz). To enable more efficient operation of large, heavy equipment, utility companies provide commercial and industrial locations with three phase AC power which consists of three overlapping sine waves offset by 120 degrees.
Although utility companies strive to distribute 100% sine wave power, many factors can introduce electrical noise into the AC power signal in the form of sine wave distortions and as voltage sags, surges, spikes, or other irregularities. Sine wave power is important for the optimal functioning of sensitive desktop computers and related peripheral equipment. Without sine wave power output, microprocessor-based equipment can become inoperative or sustain damage from power signal distortions.
Active Power Factor Correction Supplies for IT Equipment
During the past thirty years, people have become more aware of the amount of energy used by IT equipment and devices. For many years, desktop computers and workstations inefficiently consumed power, partly due to the design of the power supplies which transformed AC power (from the wall outlet) to DC power (used by computers). This voltage transformation was relatively inefficient as reflected in low power factor ratings.
In 1992, the U.S. Environmental Protection Agency (EPA), in collaboration with advocates in the IT industry, developed the ENERGY STAR® program to prompt the development of energy-efficient products. Today this program is recognized as an international standard.
To comply with ENERGY STAR standards, manufacturers of desktop and workstation computers incorporate Active Power Factor Correction (Active PFC) as part of the engineering designs, enabling energy efficiencies of 95% or higher. Computers with Active PFC power supplies require sine wave AC power, as supplied by utility companies, for trouble-free operation. For this reason, sine wave UPS systems have become the best choice for backup power.
Simulated or stepped sine wave power, provided by entry-level UPS systems, may be problematic or incompatible with Active PFC devices. Sine wave power varies continuously from positive to negative. Simulated sine wave power mimics a sine wave by using a squared-off approximation. Due to this approximation, simulated sine wave power momentarily creates a zero power gap. When power is interrupted, a computer with an Active PFC power supply may not recognize incoming simulated sine wave power due to the zero output present in the approximated wave. This could cause the system to unexpectedly shut down or sustain system component stress.
Battery Equalization Technology
A chain is only as strong as its weakest link. This proverb holds true for a multi-battery string; the weakest battery reduces the performance and life of the entire battery string. Battery Equalization Technology is an advanced charging process that improves the performance and extends the life of a multi-battery string by charging each battery to a similar voltage.
By charging each battery to a similar voltage, the multi-battery string will charge and discharge at the same level. This improves runtime and extends the time between each battery replacement resulting in lower overall battery costs.
Battery Equalization Technology is a component of a Battery Management System and has been used at the datacenter level for many years. However, this technology has not been available at the individual UPS level until now.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |