Tripp Lite Switched PDUMH30ATNET 25-Outlets PDU Rack-mountable 2U
Tripp Lite Switched PDUMH30ATNET 25-Outlets PDU Rack-mountable 2U
Tripp Lite PDUMH30ATNET
- Free Shipping
- 1 Jahr. Garantie
- 30-tägige Rückgabe
- Klimaneutral
Produkthauptmerkmale
- Einphasig 30A 120V Automatischer Umschalter / ATS PDU; Hochzuverlässiges Solid-State-Schalten
- Ermöglicht eine redundante A/B-Stromoption für nicht redundante Netzwerkgeräte
- Integrierte LX Platform Netzwerkschnittstelle
- 2U-Rackmontage, 2 L5-30P-Eingänge, 25 geschaltete Steckdosen (24 5-15/20R, 1 L5-30R)
- Einzeln schaltbare Steckdosen und integrierte Netzwerkschnittstelle ermöglichen Fernsteuerung und -überwachung
Stunden
Minuten
Versandinformationen
Tripp Lite Switched PDUMH30ATNET 25-Outlets PDU Rack-mountable 2U
Tripp Lite PDUMH30ATNET
- Free Shipping
- 1 Jahr. Garantie
- 30-tägige Rückgabe
- Klimaneutral
Stunden
Minuten
Versandinformationen
Produkthauptmerkmale
- Einphasig 30A 120V Automatischer Umschalter / ATS PDU; Hochzuverlässiges Solid-State-Schalten
- Ermöglicht eine redundante A/B-Stromoption für nicht redundante Netzwerkgeräte
- Integrierte LX Platform Netzwerkschnittstelle
- 2U-Rackmontage, 2 L5-30P-Eingänge, 25 geschaltete Steckdosen (24 5-15/20R, 1 L5-30R)
- Einzeln schaltbare Steckdosen und integrierte Netzwerkschnittstelle ermöglichen Fernsteuerung und -überwachung
Tripp Lite
PDUMH30ATNET
Tripp Lite Switched ATS / Auto Transfer Switch bietet eine redundante Stromoption für netzwerkfähige Geräte mit einem Kabel. Zwei Eingangskabel unterstützen separate Anschlüsse an die primäre und sekundäre Stromquelle. Der ATS wird normalerweise kontinuierliche Ausgabe an alle Steckdosen aus dem primären Eingangskabel abgeleitet aufrechterhalten. Wenn die primäre Stromquelle instabil wird oder ganz ausfällt, schaltet der ATS auf die sekundäre Stromquelle um, bis der primäre Eingang wiederhergestellt und stabil ist. Das hochzuverlässige Solid-State-Schalten zwischen primären und sekundären Eingängen erfolgt in 1-5 Millisekunden. Zu den Merkmalen des geschalteten PDUs gehören einzeln steuerbare Ausgangssteckdosen und eine integrierte Netzwerkschnittstelle. Der superschnelle Umschwung zwischen primärer und sekundärer Stromquelle erfolgt innerhalb von Millisekunden. Die ATS-Funktionalität wird von zwei kompatiblen AC-Stromquellen unterstützt, unabhängig von der Phasenlage, um eine Vielzahl fortschrittlicher redundanter Stromnetzanwendungen zu unterstützen. Ermöglicht eine fehlertolerante, hot-swappable UPS-Schutzfunktion, wenn sie mit einer einzigen USV verwendet wird, und vollständig redundanten UPS-Schutz, wenn jedes Kabel mit einem separaten UPS-System verbunden ist. In einer Zwei-USV-Umgebung muss das primäre Eingangskabel von einer UPS mit vollständiger Sinuswelle ohne Übertragungszeit unterstützt werden. Die SmartOnline-Serie von Tripp Lite wird für den Einsatz als primäre UPS in einer Zwei-UPS-Anwendung dringend empfohlen. ATS-Konfigurationen, die separate Hauptstromkreise, Backup-Generatoren und sogar separate Stomnetzleitungen unterstützen, werden vollständig unterstützt. Der integrierte ATS-Prozessor bewertet ständig die Stromqualität auf beiden Eingangsquellen, um einen Wechsel zur sekundären Quelle zu verhindern, wenn diese nicht verfügbar ist oder von geringerer Qualität als die primäre Quelle ist. Vorderseitige Eingangs-LEDs zeigen die Verfügbarkeit von primärer oder sekundärer Stromversorgung an. Integrierte Netzwerk-Management-Schnittstellenkarte LX Platform. Die Java-freie LX Platform HTML5-basierte Netzwerkschnittstelle ermöglicht den vollständigen Remote-Zugriff zur Statusüberwachung des PDU und E-Mail-Benachrichtigungen über einen sicheren Webbrowser, SNMP, Telnet oder SSH. Sie unterstützt 10/100 Mbps Autosensing für optimale Kommunikation mit einem Ethernet-Netzwerk. Optionale EnviroSense2-Module (separat erhältlich) bieten eine Vielzahl von Umweltüberwachungsfunktionen. Unterstützte Protokolle sind HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP und NTP.
2.9kW Single-Phase ATS/Switched PDU Provides a Redundant Power Option
Tripp Lite’s PDUMH30ATNET ATS/Switched PDU provides all the management features of a switched PDU, plus a redundant 120V power option for single-corded network devices in data centers, network closets, server rooms, computer rooms and other environments requiring network-grade power. This PDU has 25 switched outlets (24 NEMA 5-15/20R and 1 L5-30R) and supports mounting in 2U of rack space, on a wall or under a counter.
Product Specifications
Primary and Secondary Inputs for Power Redundancy
To provide redundant power for network devices, this PDU has dual 10 ft. (3 m) input power cords with NEMA L5-30P plugs for connection to compatible AC power sources, including separate mains circuits, backup generators and separate utility power grid feeds. Dual inputs also enable fault tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full-time sine wave UPS with zero transfer time, such as a Tripp Lite SmartOnline UPS.
Switches to Secondary Power Source in Milliseconds
The easy-to-read two-character LCD load meter displays the total connected equipment load, as well as the loads carried by both banks, so you can assure proper load balancing. By monitoring the total load in real time, you allow equipment to be safely connected with no danger of overloading the PDUMH30NET or power supply circuits.
Control Individual Outlets from Anywhere 24/7
For a higher level of network power control, the 16 NEMA 5-15/20R outlets can be individually controlled in real time. These controllable outlets enable power management tasks, including load shedding, load ramping, programming power-on and power-off sequences, and rebooting of locked-up network devices, to be performed remotely. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime. Unused outlets can be disabled to prevent the connection of unauthorized equipment loads. Each outlet has an LED that illuminates to confirm power on/off status.
Offers Individual Outlet Control from Anywhere
The PDUMH30NET’s all-metal case is designed to endure in demanding work environments. The locking NEMA L5-30P plug and included cord retention brackets for the outlets help prevent the PDU and its connected equipment from becoming accidentally disconnected. Real-time clock backup maintains the time of day and date, even if the PDU is shut down and unpowered.
Versatile Installation Options
The PDUMH30NET mounts in 2U of space in EIA-standard 19-inch 2-post and 4-post racks using the included mounting brackets. You can install the PDU with outlets facing either the front or rear, whichever direction offers better airflow or equipment access. You can also use the mounting brackets to install the PDU on or under a counter.
Upgradable Firmware
To support any future product enhancements, the PDU’s firmware can be manually upgraded.
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is a leading manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosures, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 95 years of quality products and service, Tripp Lite is a brand you can trust.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |