Tripp Lite Switched PDUMH30ATNET 25-Outlet PDU Rack-monterbar 2U
Tripp Lite Switched PDUMH30ATNET 25-Outlet PDU Rack-monterbar 2U
Tripp Lite PDUMH30ATNET
- Free Shipping
- 1 År Garanti
- 30 dages returret
- Kulstofneutral.
Produktets nøglefunktioner
- Enkelt fase 30A 120V Auto Transfer Switch / ATS PDU; Meget pålidelig solid state switching
- Muliggør redundant A/B strøm mulighed for ikke-redundante netværksenheder
- Indbygget LX Platform netværksinterface
- 2U rackmonterbar, 2 L5-30P indgange, 25 tændte stik (24 5-15/20R, 1 L5-30R)
- Individuelt tændte stik og indbygget netværksinterface muliggør fjernstyring og overvågning
timer
minutter
Forsendelsesoplysninger
Tripp Lite Switched PDUMH30ATNET 25-Outlet PDU Rack-monterbar 2U
Tripp Lite PDUMH30ATNET
- Free Shipping
- 1 År Garanti
- 30 dages returret
- Kulstofneutral.
timer
minutter
Forsendelsesoplysninger
Produktets nøglefunktioner
- Enkelt fase 30A 120V Auto Transfer Switch / ATS PDU; Meget pålidelig solid state switching
- Muliggør redundant A/B strøm mulighed for ikke-redundante netværksenheder
- Indbygget LX Platform netværksinterface
- 2U rackmonterbar, 2 L5-30P indgange, 25 tændte stik (24 5-15/20R, 1 L5-30R)
- Individuelt tændte stik og indbygget netværksinterface muliggør fjernstyring og overvågning
Tripp Lite
PDUMH30ATNET
Tripp Lite Switched ATS / Auto Transfer Switch giver en redundant strømmulighed for enkelt-ledede netværksenheder. Dobbelt inputkabler understøtter separat forbindelse til PRIMÆR- og SEKUNDÆR strømkilder. ATS'en opretholder normalt kontinuerlig output til alle stikkontakter som afledt fra det primære inputkabel. Hvis den primære strømkilde bliver ustabil eller helt svigter, vil ATS'en skifte over til den sekundære strømkilde, indtil det primære input genoprettes og er stabilt. Meget pålidelig solid-state omkobling mellem primære og sekundære inputs finder sted på 1-5 millisekunder. Switched PDU-funktioner inkluderer individuelt kontrollerbare outputstik og indbygget netværksinterface. Superhurtig omkobling mellem primære og sekundære strømkilder sker inden for millisekunder. ATS-funktionalitet understøttes af alle to kompatible AC-strømkilder, uanset fasevinkel, for at støtte en række avancerede redundante strømnetsværksapplikationer. Muliggør fejltolerant, hot-swappable UPS-beskyttelse, når den bruges med en enkelt UPS, og fuldt redundant UPS-beskyttelse, når hvert kabel er tilsluttet et separat UPS-system. I et to-UPS miljø skal det primære inputkabel understøttes af en heltid sinuskurve UPS med nul overførselstid. Tripp Lite SmartOnline serien anbefales kraftigt til brug som den primære UPS i en to-UPS applikation. ATS-konfigurationer, der benytter separate netledninger, backupgeneratorer og endda separate forsyningsnet, understøttes fuldt ud. Den indbyggede ATS-processor evaluerer konstant strømkvaliteten på begge inputkilder for at forhindre overførsel til den sekundære kilde, når den ikke er tilgængelig eller af lavere kvalitet end den primære kilde. Frontinput LED'er viser tilgængeligheden af primær eller sekundær strøm. Indbygget LX Platform netværksstyringsinterfacekort. Den Java-fri LX Platform HTML5-baserede netværksinterface muliggør fuld fjernadgang til PDU-statusovervågning og e-mail-notifikationer via sikker webbrowser, SNMP, telnet eller SSH. Den understøtter 10/100 Mbps auto-sensing for optimal kommunikation med et Ethernet-netværk. Valgfri EnviroSense2-moduler (sælges separat) giver en række miljøovervågningsmuligheder. Understøttede protokoller inkluderer HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP og NTP.
2.9kW Single-Phase ATS/Switched PDU Provides a Redundant Power Option
Tripp Lite’s PDUMH30ATNET ATS/Switched PDU provides all the management features of a switched PDU, plus a redundant 120V power option for single-corded network devices in data centers, network closets, server rooms, computer rooms and other environments requiring network-grade power. This PDU has 25 switched outlets (24 NEMA 5-15/20R and 1 L5-30R) and supports mounting in 2U of rack space, on a wall or under a counter.
Product Specifications
Primary and Secondary Inputs for Power Redundancy
To provide redundant power for network devices, this PDU has dual 10 ft. (3 m) input power cords with NEMA L5-30P plugs for connection to compatible AC power sources, including separate mains circuits, backup generators and separate utility power grid feeds. Dual inputs also enable fault tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full-time sine wave UPS with zero transfer time, such as a Tripp Lite SmartOnline UPS.
Switches to Secondary Power Source in Milliseconds
The easy-to-read two-character LCD load meter displays the total connected equipment load, as well as the loads carried by both banks, so you can assure proper load balancing. By monitoring the total load in real time, you allow equipment to be safely connected with no danger of overloading the PDUMH30NET or power supply circuits.
Control Individual Outlets from Anywhere 24/7
For a higher level of network power control, the 16 NEMA 5-15/20R outlets can be individually controlled in real time. These controllable outlets enable power management tasks, including load shedding, load ramping, programming power-on and power-off sequences, and rebooting of locked-up network devices, to be performed remotely. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime. Unused outlets can be disabled to prevent the connection of unauthorized equipment loads. Each outlet has an LED that illuminates to confirm power on/off status.
Offers Individual Outlet Control from Anywhere
The PDUMH30NET’s all-metal case is designed to endure in demanding work environments. The locking NEMA L5-30P plug and included cord retention brackets for the outlets help prevent the PDU and its connected equipment from becoming accidentally disconnected. Real-time clock backup maintains the time of day and date, even if the PDU is shut down and unpowered.
Versatile Installation Options
The PDUMH30NET mounts in 2U of space in EIA-standard 19-inch 2-post and 4-post racks using the included mounting brackets. You can install the PDU with outlets facing either the front or rear, whichever direction offers better airflow or equipment access. You can also use the mounting brackets to install the PDU on or under a counter.
Upgradable Firmware
To support any future product enhancements, the PDU’s firmware can be manually upgraded.
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is a leading manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosures, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 95 years of quality products and service, Tripp Lite is a brand you can trust.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |