APC AP8962 PDU رف محول، 24 مخرج، 5760 VA، 230V مدخل، 120V مخرج

Front view of APC AP8962 Switched Rack PDU showing 24 NEMA outlets and digital control interface-alternate-image1
Side profile of APC AP8962 PDU showing vertical mounting configuration and outlet arrangement-alternate-image2
Detail view of APC AP8962 PDU circuit breakers and management interface-alternate-image3
Profile view showing the robust construction of APC AP8962 PDU housing-alternate-image4

APC AP8962 PDU رف محول، 24 مخرج، 5760 VA، 230V مدخل، 120V مخرج

APC AP8962

5,353.00 SR 8,053.00 SR وفر 2,700 SR
الشريك المعتمد
علامة تجارية جديدة
التوفر: في المخزون ، جاهز للشحن .
  • Free Shipping
  • سنة واحدة الضمان
  • 30 يومًا للإرجاع
  • محايدة مناخيا للكربون

ميزات مفتاح المنتج

  • إمكانية التركيب العمودي - يُركب بسهولة عموديًا في الرفوف أو الصناديق ويشغل صفر مساحة في الرف المهمة، مما يسمح بوضع المزيد من المعدات في الرف. الوحدات التي تُركب عموديًا محسنة لتناسب صناديق NetShelter.
5,353.00 SR
مجانية الإرجاع
توصيل مجاني
اطلب في المرة القادمة

ساعات

دقائق

أن يتم تسليمه في

معلومات الشحن

-
+
اتصل بنا الآن
888.267.9566
Minimize
Info
Info Page
Reviews Top
×

×
  • وصف
  • مواصفات التقنية
  • سياسة الاسترداد

APC

AP8962

APC AP8962 Switched Rack PDU - 24 Outlet Power Distribution Unit with Advanced Monitoring

The APC AP8962 Switched Rack PDU delivers enterprise-grade power distribution with 5760 VA capacity and advanced remote management capabilities. This 0U form factor PDU features 24 NEMA 5-20R outlets, converting 230V input to 120V output, making it ideal for high-density rack environments requiring precise power control and monitoring.

Advanced Power Management and Control Features

Experience comprehensive power management with outlet-level switching capabilities for remote power cycling and equipment rebooting. The PDU supports customizable power sequencing, enabling defined power-up sequences to prevent inrush current issues. Real-time current metering and user-defined alarms provide proactive circuit overload prevention.

Remote Management Capabilities

  • Secure web interface for remote configuration
  • SNMP protocol support for network management
  • Telnet interface for command-line control
  • Compatible with InfraStruxure Central, Capacity Manager, and Change Manager

Technical Specifications and Power Details

  • Input: 230V AC with NEMA L21-20P connector
  • Output: 120V AC through 24 NEMA 5-20R outlets
  • Power Capacity: 5760 VA with 20A input current
  • Built-in circuit breaker protection
  • 6-foot power cord length
  • Versatile 0U mounting options (Horizontal/Vertical)
  • Dimensions: 70.5" x 2.2" x 1.7"

Installation and Safety Compliance

The AP8962 meets stringent safety standards including UL 60950-1, cUL Listed, and FCC Part 15 Class A certifications. Environmental compliance includes RoHS and REACH standards, ensuring sustainable deployment in modern data centers.

Package Contents

  • Switched Rack PDU
  • Installation guide
  • Rack mounting brackets
  • Safety guide
  • Serial configuration cable
وحدات توزيع الطاقة الموزعة (PDUs) من نوع APC المبدلة تتيح التحكم المتقدم في الطاقة والمراقبة النشطة القابلة للتخصيص من قبل المستخدم. تتيح عناصر التحكم على مستوى المخرج عن بُعد وظيفة تشغيل/إيقاف الطاقة لإعادة تدوير الطاقة عن بُعد لإعادة تشغيل المعدات وتقييد الاستخدام غير المصرح به للمخارج الفردية. تسمح تأخيرات ترتيب الطاقة للمستخدمين بتحديد الترتيب الذي يتم فيه تشغيل أو إيقاف تشغيل المعدات المتصلة. تجنب زيادة التحميل على الدائرة خلال استعادة الطاقة وامتد فترة تشغيل المعدات الحرجة من خلال إعطاء الأولوية لتخفيف الحمل. يوفر قياس التيار مراقبة عن بُعد في الوقت الحقيقي للأحمال المتصلة. تتضمن وحدات PDUs المبدلة مراقبة للطاقة الحقيقية، ومنفذ لمستشعر درجة الحرارة / الرطوبة، ومآخذ IEC مقفلة، وقواطع دوائر منخفضة الارتفاع. تحذر المنبهات المعرفة من قبل المستخدم من زيادة التحميل المحتملة على الدائرة قبل حدوث فشل حرج في تكنولوجيا المعلومات. يمكن للمستخدمين الوصول إلى، وتكوين، والتحكم في وحدات PDUs المبدلة من خلال واجهات الويب الآمنة، وSNMP، أو Telnet، ويتم تكملتها بواسطة منصات الإدارة المركزية من APC باستخدام InfraStruxure Central، وCapacity Manager، وChange Manager.

Return Policy

Time to Return

Standard Return Policy

We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.

Replacement Only Return Policy

Replacement within 30 days of the delivery date.

Manufacturer Only Return Policy

Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.

Holiday Extended Return Policies

Extended Holiday Return Policy.

Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024.


Extended Holiday Replacement-Only Return Policy

Qualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.

أسئلة وأجوبة
The APC AP8962 is a sophisticated Switched Rack PDU featuring 24 NEMA 5-20R outlets with remote outlet-level control, 5760 VA capacity, and 230V input/120V output capability. Key features include real-time power monitoring, remote power cycling, user-customizable power sequencing, temperature/humidity sensor port, and locking IEC receptacles. It supports management through Web, SNMP, or Telnet interfaces and includes low-profile circuit breakers for protection. The unit can be monitored and controlled through APC's InfraStruxure Central, Capacity Manager, and Change Manager platforms.
The AP8962 PDU operates with a 230V AC input and provides 120V AC output, delivering a power rating of 5760 VA. It features a 20A input current capacity and includes circuit breaker protection. The unit comes with 24 NEMA 5-20R receptacles and uses a NEMA L21-20P plug/connector type, making it suitable for high-density power distribution in rack environments.
Users can manage the AP8962 PDU through multiple secure interfaces including Web, SNMP, and Telnet. The unit provides real-time remote monitoring of connected loads, user-defined alarms for potential circuit overloads, and customizable power sequencing capabilities. It integrates with APC's centralized management platforms (InfraStruxure Central, Capacity Manager, and Change Manager) for comprehensive power management and monitoring.
The AP8962 PDU is designed for flexible 0U rack mounting in either horizontal or vertical orientation. It measures 70.5" in height, 2.2" in width, and 1.7" in depth, weighing approximately 15.33 lb. The unit comes in black and includes a 6-foot power cord. Rack mounting brackets are included for easy installation, making it ideal for efficient space utilization in data center racks.
The AP8962 PDU holds multiple safety certifications including cUL Listed, UL Listed, UL 60950-1, FCC Part 15 Class A, and ICES-003 compliance. It's also environmentally certified with RoHS and REACH standards, ensuring it meets strict safety and environmental requirements for data center equipment.
The AP8962 PDU package includes the Switched Rack PDU unit, an installation guide, rack mounting brackets, a safety guide, and a serial configuration cable. All components necessary for proper installation and initial setup are provided in the package, supported by a 2-year limited warranty.
The power sequencing feature on the AP8962 PDU allows users to define specific order and timing for powering up or down connected equipment. This functionality helps prevent inrush current during power restoration, enables systematic equipment startup, and supports load shedding prioritization. Users can customize delays between outlet activations to ensure critical equipment is powered in the correct sequence.
The AP8962 PDU includes several load protection features such as low-profile circuit breakers, user-defined alarm systems that warn of potential circuit overloads before critical failures occur, and real-time power monitoring capabilities. The unit also supports load shedding functionality to maintain uptime for critical equipment during power events, and provides detailed current metering for connected loads.