C2G 00905 9ft Cat6 钩纹屏蔽(STP)网络补丁电缆 - 紫色,模制,多股,铜,镀金/镍光连接器 品牌名称翻译:C2G - 信号到导管

Close-up view of purple Cat6 cable's shielded RJ-45 connector with gold-plated contacts and snagless boot-alternate-image1
Side angle view of purple Cat6 network cable showing shielded connector and cable construction-alternate-image2

C2G 00905 9ft Cat6 钩纹屏蔽(STP)网络补丁电缆 - 紫色,模制,多股,铜,镀金/镍光连接器 品牌名称翻译:C2G - 信号到导管

C2G 00905

$37.00
更新
优良的条件
可用性: 有现货 准备好发货 .
  • Free Shipping
  • 1年 保修
  • 30天退货
  • 碳中和

产品关键特征

  • 9英尺Cat6防护(STP)网络数据线,紫色
  • 终身有限保修,让您放心
  • UL94V-0和ANSI/TIA 568 C.2 Cat6认证,保证高质量性能
  • 成型和绞线设计,灵活耐用
  • 防绞保护头,防止电缆缠绕和损坏
  • 铜导体,可靠数据传输
  • 屏蔽层,防止电磁干扰
  • Cat6类网缆,提供快速可靠网络连接
  • 9英尺长度,方便安装
  • 兼容网络设备
$37.00
免费退货
免费送货
在下一个订单中

小时

分钟

交货日期

航运资讯

-
+
请问我们的专家
立即致电给我们
888.267.9566
Minimize
Info
Info Page
Reviews Top
×

×
  • Description
  • 技术规格
  • 退款政策

C2G

00905-Excellent

C2G 9ft Cat6 Snagless Shielded Network Cable - Premium STP Patch Cable for High-Speed Networks

Experience superior network performance with the C2G 9ft Cat6 Snagless Shielded (STP) Network Patch Cable. This professional-grade purple patch cable features gold and nickel-plated connectors, stranded copper conductors, and comprehensive shielding for optimal protection against electromagnetic interference in demanding network environments.

Advanced Shielding Technology for Superior Performance

This Cat6 STP cable is engineered with premium shielding technology to protect your high-speed network connections from EMI and noise interference. The cable's construction ensures reliable performance for bandwidth-intensive applications while significantly reducing both impedance and structural return loss (SRL).

Professional-Grade Specifications

  • Fully tested to meet ANSI/TIA 568 C.2 Cat6 component requirements
  • Snagless boot design for easy installation and removal
  • Gold and nickel-plated connectors for superior conductivity
  • Stranded copper conductors for enhanced flexibility
  • Purple jacket color for easy network identification
  • 9-foot length with individual length label

Enhanced Cable Construction for Maximum Reliability

Each pair within the cable is precisely bonded to maintain optimal twist-spacing throughout the entire length, extending right to the termination points. This specialized construction technique minimizes Near-End Crosstalk (NEXT) levels, ensuring consistent, high-quality network performance for your data, voice, and video applications.

Technical Specifications and Compatibility

  • RJ-45 male connectors on both ends for universal network device compatibility
  • PVC jacket material meeting UL94V-0 standards
  • Supports all Cat6 network applications
  • Approximate weight: 0.30 lb
  • Backed by lifetime warranty
保护高速网络免受噪音和电磁干扰,连接我们的Snagless Shielded Cat6补丁电缆。对于语音/数据/视频分发,该电缆将处理带宽密集型应用程序,并显着降低阻抗和结构回波损耗(SRL)。每根补丁电缆均经过全面测试,以满足ANSI/TIA 568 C.2 Cat6组件要求。每对单独的线束均被粘合在一起,以帮助在整条线路上保持绞距,直至终端点。采用优质电缆和插头构造,此设计最大程度地减少了近端串扰(NEXT)级别。提供多种颜色可供选择,方便进行网络安装的颜色编码。每根电缆上都有个别长度标签,方便使用。

Return Policy

Time to Return

Standard Return Policy

We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.

Replacement Only Return Policy

Replacement within 30 days of the delivery date.

Manufacturer Only Return Policy

Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.

Holiday Extended Return Policies

Extended Holiday Return Policy.

Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024.


Extended Holiday Replacement-Only Return Policy

Qualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.

Close-up view of purple Cat6 cable's shielded RJ-45 connector with gold-plated contacts and snagless boot

Enhanced EMI Protection with Gold-Plated Shielded Connector

The precision-engineered RJ-45 connector features gold and nickel plating for superior conductivity and corrosion resistance. The purple-jacketed cable incorporates advanced shielding technology that effectively blocks electromagnetic interference, ensuring consistent data transmission in noise-sensitive environments. The snagless boot design protects the locking tab while making it easy to insert and remove the connector without snagging.

Technical Specifications

  • Gold and nickel-plated contacts for optimal signal integrity
  • Snagless molded boot design for secure connections
  • STP shielding for EMI/RFI protection

Applications

  • Data center rack-to-rack connections
  • Network infrastructure in industrial environments
  • High-interference areas requiring signal protection
Side angle view of purple Cat6 network cable showing shielded connector and cable construction

Industrial-Grade Construction for Reliable Performance

The stranded copper conductors and robust PVC jacket provide flexibility and durability for demanding installation environments. Each twisted pair is precisely bonded to maintain optimal spacing, reducing crosstalk and ensuring consistent Cat6 performance. The premium construction supports bandwidth-intensive applications while meeting strict ANSI/TIA 568 C.2 standards for reliable enterprise networking.

Technical Specifications

  • Stranded copper conductors for installation flexibility
  • Bonded pair technology for consistent performance
  • UL94V-0 rated PVC jacket for safety compliance

Applications

  • Enterprise network backbone installations
  • Server room patching and cross-connects
  • Mission-critical network infrastructure
常见问题
The C2G 00905 is a 9-foot Cat6 Snagless Shielded (STP) network cable featuring gold/nickel plated connectors, molded construction, and stranded copper conductors. It's designed with snagless boots, purple PVC jacket, and RJ-45 male connectors on both ends. The cable is fully shielded to protect against EMI/RFI interference and meets ANSI/TIA 568 C.2 Cat6 standards for high-speed network performance.
This cable uses RJ-45 Network Male connectors on both ends with gold and nickel plating. The connectors feature snagless boots to protect the locking tabs during installation and removal. The gold/nickel plating ensures optimal conductivity and corrosion resistance for reliable long-term performance.
Yes, this is a Shielded Twisted Pair (STP) cable, which provides protection against electromagnetic interference (EMI) and radio frequency interference (RFI). The shielding is crucial for maintaining signal integrity in environments with electrical noise, making it ideal for data centers, industrial settings, or areas with high electromagnetic activity. This shielding helps minimize crosstalk and ensures reliable high-speed data transmission.
As a Cat6 cable meeting ANSI/TIA 568 C.2 standards, this cable supports bandwidth-intensive applications with speeds up to 1 Gigabit per second (Gbps) at 100 meters and 10 Gbps at shorter distances. The cable's design minimizes Near-End Crosstalk (NEXT) levels and structural return loss (SRL) to maintain optimal performance for voice, data, and video distribution.
The C2G 00905 Cat6 network cable comes with a Lifetime Limited Warranty, providing long-term protection for your investment. This warranty demonstrates C2G's confidence in the cable's build quality and performance reliability over extended periods of use.
The snagless feature refers to the specially designed boot on the RJ-45 connectors that protects the locking tabs from snagging or breaking during cable installation and removal. This design is particularly important when routing cables through tight spaces or when frequently connecting and disconnecting the cable, extending its lifespan and maintaining reliable connectivity.
This cable meets several important certifications including UL94V-0 for flame resistance and ANSI/TIA 568 C.2 Cat6 component requirements. Each cable is fully tested to ensure compliance with these standards, guaranteeing high-quality performance and safety in network installations.
The C2G 00905 is a 9-foot (2.74 meters) long cable with a purple PVC jacket. It weighs approximately 0.30 pounds and features stranded copper conductors. The cable's molded construction and high-quality materials ensure durability while maintaining flexibility for easy installation.