- Bảo vệ thiết bị nhạy cảm khỏi tiếng ồn và sự cố EMI/RFI
- Dòng rò tích lũy dưới 50 µA
- Tự động ngắt kết nối tất cả các ổ cắm trong trường hợp quá tải
- Cung cấp sự cách ly hoàn toàn khỏi nguồn AC đầu vào
- Lý tưởng cho việc sử dụng trong bất kỳ môi trường công nghiệp, mạng lưới hoặc y tế nào
hrs
mins
Thông tin vận chuyển
Tripp Lite
IS300HGDV
An internal low-impedance isolation transformer component offers 100% isolation from the input mains AC line. Faraday shield reduces the cumulative leakage current of the IS300HGDV and connected equipment to levels less than 50 microamps, while removing utility switching transients and harmonics generated by other on-site loads and reducing the impact of utility or lightning related surge conditions.
Transformer filtering provides continuous common-mode noise rejection with no wearable parts. The IS300HGDV reduces 6000V IEEE 587 Category A and B ring wave and combination wave test surges to only 0.5V common mode.
Components connect to four C13 outlets with fuse overload protection and a lighted on/off switch. The rugged all-metal unit housing ships ready for placement in any industrial, medical, office, network or audio/video environment. Requires a C14-to-C13 AC input cord (sold separately).. ``` Chuyển đổi sang tiếng Việt: ```html Biến áp Isolator® Series Dual-Voltage 115/230V 300W 50/60Hz Medical-Grade™ IS300HGDV với đầy đủ CAN/ES/IEC/EN 60601-1 là lý tưởng để bảo vệ thiết bị điện tử nhạy cảm trong khu vực chăm sóc bệnh nhân. Nó có thể được cấu hình cho hoạt động nâng điện áp, hạ điện áp hoặc điện áp đi qua. Cùng với việc cách ly đường dây và lọc tiếng ồn EMI/RFI liên tục, chỉ số bảo vệ quá điện áp của nó là 240 joules giảm thiểu điện áp dư để ngăn chặn hư hại cho thiết bị kết nối.
Một thành phần biến áp cách ly có điện trở thấp bên trong cung cấp 100% cách ly khỏi đường dây AC chính đầu vào. Màng Faraday giảm thiểu dòng rò tích lũy của IS300HGDV và thiết bị kết nối xuống mức dưới 50 microamps, trong khi loại bỏ các dao động chuyển mạch của tiện ích và các hài được tạo ra bởi các tải khác tại chỗ và giảm thiểu ảnh hưởng của các điều kiện tăng áp liên quan đến tiện ích hoặc sét.
Lọc biến áp cung cấp loại bỏ tiếng ồn chế độ chung liên tục mà không có bộ phận hao mòn. IS300HGDV giảm 6000V IEEE 587 hạng A và B đợt sóng và đợt sóng kết hợp thử nghiệm giảm xuống chỉ còn 0.5V chế độ chung.
Các thành phần kết nối với bốn ổ cắm C13 có bảo vệ quá tải bằng cầu chì và một công tắc bật/tắt có đèn. Vỏ thiết bị kim loại chắc chắn được vận chuyển sẵn sàng để đặt tại bất kỳ môi trường công nghiệp, y tế, văn phòng, mạng hoặc âm thanh/video nào. Cần một dây AC đầu vào C14 đến C13 (bán riêng).. ```
Tripp Lite IS300HGDV Product Summary
- Transformer with full CAN/ES/IEC/EN 60601-1 listing for patient care vicinities
- Offers line isolation, step-up and step-down capabilities, and continuous noise filtering
- Faraday shield offers 100% isolation from input AC line
- Cumulative leakage current less than 50 µA
- 300W continuous capacity with 4 C13 outlets
- Selectable 115V/230V input/output voltage
- 240 joules of AC surge protection
Typical Applications
- Protect lab equipment in patient care vicinities where an isolated ground is essential for safe operation of sensitive electronics
- Prevent misdiagnosis due to artifacts and shadowing caused by EMI/RFI line noise in imaging and diagnostic centers
- Use a 120V device in a facility with 230V input (or a 230V device with 120V input)
- Lower the accumulative leakage current to levels required for UL 60601-1 compliance within patient care vicinities
Medical-Grade Transformer Isolates and Protects Valuable Equipment in Patient Care Vicinities
The IS300HGDV Medical-Grade™ Transformer, part of Tripp Lite’s acclaimed Isolator® series, with full CAN/ES/IEC/EN 60601-1 listing is ideal for protecting sensitive electronics, including diagnostic and lab equipment, in patient care vicinities. UL 60601-1 compliance is required for isolation transformers within patient care vicinities to avoid hazardous conditions and provide an optimally safe environment for patients, staff and visitors.
High-Capacity, Dual-Voltage Unit Ensures Equipment Safety in Hazardous Conditions
At 300 watts, the IS300HGDV can handle a variety of essential devices. Selectable 115V/230V input/output voltage with step-up, step-down or pass-through operation is also suitable for a wide range of devices and facilities. A 240-joule surge protection rating suppresses excess voltage to prevent it from damaging connected equipment (the unit automatically shuts down all outlets in case of overload). Transformer filtering provides continuous common-mode EMI/RFI line noise rejection with no wearable parts. The IS300HGDV reduces 6000V IEEE 587 Category A and B ring wave and combination wave test surges to only 0.5V common mode.
Faraday Shield Design Provides Superior Line Isolation
By isolating equipment from unpredictable and disruptive utility power, the IS300HGDV eliminates the need for dedicated circuits or costly upgrades to your facility’s electrical system. With 100-percent isolation from the input mains AC line, the Faraday shield reduces the cumulative leakage current of the IS300HGDV and connected equipment to levels less than 50 microamps. It also removes utility switching transients and harmonics generated by other on-site loads and reduces the impact of utility- or lightning-related surge conditions.
Equi-Potential Earth Connection
The IS300HGDV has both a potential equalization bolt (POAG) and an earth ground lug connector, which can be used for connecting to equi-potential earthing equipment terminals. The transformer can then be connected to other medical instruments. The POAG connection complies with the Medical Safety Standard EN 60601-1. Use the equi-potential earth screw to connect to any equipment that requires equi-potential earth connection and does not have a POAG connection.
Ships Ready for Immediate Placement in Your Busy Environment
The rugged all-metal housing is designed to withstand frequent use in demanding industrial, medical, office, network and audio/video applications. Equipment plugs into four C13 outlets with fuse overload protection. A lighted on/off switch controls current to all four outlets. A C14-to-C13 input cord (sold separately) is required for connecting the transformer to AC power.
What’s in the Box
- IS300HGDV Dual-Voltage Medical-Grade Isolation Transformer
- (2) Fuse Sets (115V and 230V Operation)
- Input/Output Cable Selector Data Sheet
- Owner's Manual
Environmentally Responsible Design
It’s manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite’s commitment to environmental responsibility.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |