C2G 1ft Cat6 Snagless Shielded Network Cable with EMI Protection
Experience superior network performance with the C2G 00842 Cat6 Snagless Shielded (STP) Network Patch Cable. This professional-grade 1-foot red ethernet cable features advanced EMI protection and gold-plated connectors, making it ideal for high-speed data transmission in noise-sensitive environments.
Premium Shielded Design for Maximum Performance
This Cat6 network patch cable features a specialized shielded twisted pair (STP) design that effectively blocks electromagnetic interference (EMI) and minimizes Near-End Crosstalk (NEXT). The cable's bonded pair construction maintains precise twist spacing up to the termination point, ensuring optimal signal integrity for bandwidth-intensive applications.
Key Features:
Snagless boot design for easy installation
Gold and nickel-plated connectors for superior conductivity
Stranded copper conductor for flexibility
PVC jacket in vibrant red for easy identification
ANSI/TIA 568 C.2 Cat6 certified performance
Professional-Grade Connectivity Specifications
Each end of the cable features a male RJ-45 connector with gold plating for optimal signal transfer and corrosion resistance. The snagless boot design protects the locking tab while preventing unwanted cable snags during installation. This cable is perfect for connecting network devices in data centers, server rooms, or office environments.
Quality Assurance and Certification
Every C2G Cat6 patch cable undergoes rigorous testing to meet ANSI/TIA 568 C.2 Cat6 component requirements. The cable is UL94V-0 certified for safety and comes with a lifetime warranty, ensuring long-term reliability for your network infrastructure investments.
แบบเชื่อมต่อสาย,ขึ้นรูป,การป้องกัน EMI,Near End Cross Talk (NEXT)
ประเภทบูท
Snagless
การป้องกัน
ใช่
ตัวนำไฟฟ้า
ทอง
ประเภทเคเบิล
หมวดหมู่ 6
ความยาวเคเบิล
1 ฟุต
ภูมิเทคตัวต่อ
ทอง,นิกเกิล
ลักษณะของเคเบิล
เพชช์เคเบิล
อุปกรณ์ที่รองรับ
อุปกรณ์เครือข่าย
ชนิดของตัวต่อที่ปลายแรก
เครือข่าย RJ-45 - เมล
ชนิดของตัวต่อที่ปลายที่สอง
เครือข่าย RJ-45 - เมล
รายละเอียดตัวต่อที่ปลายแรก
1 x เครือข่าย RJ-45 - ผู้
รายละเอียดตัวต่อที่ปลายที่สอง
1 x เครือข่าย RJ-45 - เมล
ลักษณะทางกายภาพ
วัสดุฉนวน
โพลีไวนิล คลอไรด์
สีผลิตภัณฑ์
แดง
น้ำหนัก (โดยประมาณ)
0.06 ปอนด์
Return Policy
Time to Return
Standard Return Policy
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return
Policy
qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.
Replacement Only Return Policy
Replacement within 30 days of the delivery date.
Manufacturer Only Return Policy
Covered by the manufacturer's warranty.
Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.
Holiday Extended Return Policies
Extended Holiday Return Policy.
Qualifying purchases of products displaying the " Extended Holiday
Return Policy ",
from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31,
2024.
Extended Holiday Replacement-Only Return Policy
Qualifying purchases of products displaying the " Extended Holiday
Replacement-Only Return Policy ",
from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.
Superior EMI Protection with Gold-Plated Connectors
The C2G Cat6 shielded patch cable features a premium metal-shielded RJ-45 connector that delivers exceptional electromagnetic interference (EMI) protection. The gold-plated contacts ensure optimal signal transmission while the nickel-plated housing provides additional shielding against external interference. The red snagless boot design prevents unwanted cable snags during installation and maintenance.
Technical Specifications
Gold-plated contacts for superior conductivity and corrosion resistance
Metal-shielded RJ-45 connector for complete EMI protection
Snagless boot design for secure cable management
Applications
Data center network connections requiring EMI protection
High-Performance Snagless Design with Enhanced Durability
This Cat6 cable features a robust construction with a carefully engineered strain relief boot that maintains proper bend radius and prevents cable damage. The shielded twisted pair (STP) design with bonded pair technology ensures consistent performance up to 550 MHz. The molded connector housing provides additional durability while maintaining optimal signal integrity.
Technical Specifications
Strain relief boot maintains proper bend radius
Bonded pair technology for consistent performance
550 MHz bandwidth capacity for high-speed data transmission
Applications
Server room patch panel connections
Network switch to server connectivity
High-density network cabinet installations
FAQ
The C2G 00842 is a Cat6 Snagless Shielded (STP) network patch cable featuring EMI protection, gold and nickel connector plating, and snagless boots. It's designed with stranded copper conductors, molded construction, and provides Near End Cross Talk (NEXT) protection. The cable is 1 foot long, comes in red, and includes RJ-45 male connectors on both ends. It's fully tested to meet ANSI/TIA 568 C.2 Cat6 component requirements and comes with a lifetime warranty.
This cable offers comprehensive protection through multiple features: EMI (Electromagnetic Interference) shielding, which protects against external noise and interference, snagless boots to protect the connector tabs, and Near End Cross Talk (NEXT) protection to minimize signal interference between pairs. The cable is also UL94V-0 certified and features gold/nickel connector plating for enhanced durability and signal integrity.
The C2G 00842 features RJ-45 Network Male connectors on both ends. The connectors are plated with both gold and nickel for optimal conductivity and durability. The cable includes snagless boots to protect the connector tabs from damage during installation and removal. Each connector is molded and designed to meet ANSI/TIA 568 C.2 Cat6 component requirements for reliable network connectivity.
Yes, this Cat6 cable is specifically designed for high-speed network applications. It handles bandwidth-intensive applications and drastically reduces both impedance and structural return loss (SRL). The shielded (STP) construction, combined with bonded pairs and NEXT protection, ensures optimal performance for voice/data/video distribution. The cable meets ANSI/TIA 568 C.2 Cat6 component requirements for high-speed networking.
The cable is constructed with stranded copper conductors and features a Polyvinyl Chloride (PVC) jacket. It's built with individually bonded pairs to maintain twist-spacing throughout the line up to the termination point. The cable includes shielding (STP) for EMI protection, gold and nickel plated connectors, and snagless boots. The entire construction is molded and weighs approximately 0.06 lb.
The C2G 00842 cable meets several important certifications and standards including ANSI/TIA 568 C.2 Cat6 component requirements and UL94V-0 certification. Each patch cable is fully tested to ensure compliance with these standards, guaranteeing reliable performance and safety in network installations. These certifications ensure the cable meets industry requirements for high-speed data transmission and fire safety.
The C2G 00842 Cat6 network cable comes with a lifetime limited warranty, providing long-term protection for your investment. This warranty coverage demonstrates C2G's confidence in the cable's quality and durability, ensuring peace of mind for professional network installations and daily use.
The snagless boot design provides several key benefits: it prevents the connector's tab from catching or snagging during cable installation and removal, protects the connector from damage during routing through tight spaces, extends the cable's lifespan by preventing connector breakage, and makes installation and maintenance easier and more efficient, especially in dense network environments.