Tripp Lite PDU3MV6H50 Metered PDU 12.6 kW 45 Outlets 208V 6 ft Input Connection 트립 라이트 PDU3MV6H50 미터링 PDU 12.6 kW 45 콘센트 208V 6 ft 입력 연결
Tripp Lite PDU3MV6H50 Metered PDU 12.6 kW 45 Outlets 208V 6 ft Input Connection 트립 라이트 PDU3MV6H50 미터링 PDU 12.6 kW 45 콘센트 208V 6 ft 입력 연결
Tripp Lite PDU3MV6H50
- Free Shipping
- 1 Year Warranty
- 30 Day Returns
- Carbon Neutral
Product Key Features
- 미터링 12.6kW 3상 208V PDU; 70인치 / 178cm 0U 세로 랙마운트
- 3개의 내장된 전류계를 통해 각 상의 부하 전류를 보고합니다
- Hubbell CS8365C 50A (3P+E) 208V 3상 입력; 6피트 / 1.8m 전원 코드
- 총 45개의 208V 아웃렛 (36개의 C13, 9개의 C19)
- 공구 없이 버튼마운트 설치; 코드 보유 브라켓 포함}
Tripp Lite PDU3MV6H50 Metered PDU 12.6 kW 45 Outlets 208V 6 ft Input Connection 트립 라이트 PDU3MV6H50 미터링 PDU 12.6 kW 45 콘센트 208V 6 ft 입력 연결
Tripp Lite PDU3MV6H50
- Free Shipping
- 1 Year Warranty
- 30 Day Returns
- Carbon Neutral
hrs
mins
배송 정보
Product Key Features
- 미터링 12.6kW 3상 208V PDU; 70인치 / 178cm 0U 세로 랙마운트
- 3개의 내장된 전류계를 통해 각 상의 부하 전류를 보고합니다
- Hubbell CS8365C 50A (3P+E) 208V 3상 입력; 6피트 / 1.8m 전원 코드
- 총 45개의 208V 아웃렛 (36개의 C13, 9개의 C19)
- 공구 없이 버튼마운트 설치; 코드 보유 브라켓 포함}
Tripp Lite
PDU3MV6H50
Built-In Digital Meters Provide Visual Monitoring of 3-Phase Power Distribution
Efficiently distribute and monitor power in data center environments with Tripp Lite's PDU3MV6H50 3-Phase Metered Power Distribution Unit. Unfiltered electrical pass-through makes the PDU3MV6H50 ideal for distributing alternate waveform utility, UPS or generator power in rack enclosures and network closets. And with three digital meters, you’ll always know the current draw of connected equipment.
Reliable Network-Grade Power Distribution
The PDU3MV6H50 provides reliable 208V power service via 45 outlets in three separately breakered 20A single-phase load banks: 36 C13 outlets (12 per phase, 12 per breakered 20A load bank) and 9 C19 outlets (3 per phase, 3 per breakered 20A load bank). This PDU has a rugged all-metal housing and a 6 ft. power cord with a Hubbell CS8365C 50A twist-lock plug. Load capacity is 12.6kW.
Digital Load Meters for Real-Time VisualMonitoring
Three digital load meters provide the current level (in amps) of connected equipment in each load bank. These meters help ensure the PDU is used at maximum capacity with no danger of overload.
Versatile Installation Options IncludingToolless Installation
The PDU3MV6H50 is easy to integrate with a wide range of data center and network applications. It can be configured for 0U (vertical) rack installation with the included mounting brackets, and it also supports toolless button-mount vertical installation in compatible rack enclosures. Vertical 0U installation reduces cord clutter and promotes efficient airflow through the rack.
TAA-Compliant for GSA Schedule Purchases
The PDU3MV6H50 is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.
Tripp Lite PDU3MV6H50 Product Summary:
- Reliablepower distribution in data center environments
- 3digital meters display current draw of connected equipment
- Compact,0U vertical rackmount installation
- Ruggedall-metal housing with 45 total outlets (36 C13 and 9 C19)
- Cordretention brackets secure equipment power cords
- TAA-compliant
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |