Tripp Lite PDUMNH15AT1 8-Outlets PDU、144KW 120V Single-Phase ATS/Monitoring トリップライト PDUMNH15AT1 8-アウトレット PDU、144KW 120V シングルフェーズ ATS/モニタリング

Front view of Tripp Lite PDUMNH15AT1 PDU showing 8 outlets, digital display, and network interface-alternate-image1
Close-up view of digital display and network interface on Tripp Lite PDU-alternate-image2
Side view showing metal construction of Tripp Lite PDU chassis-alternate-image3
Angled view of PDU showing outlet arrangement and cable management features-alternate-image4
Rear view of PDU showing dual power inputs and configuration port-alternate-image5
Installation components including mounting brackets, cables, and documentation-alternate-image6
Close-up of mounting brackets, screws and installation manual-alternate-image7

Tripp Lite PDUMNH15AT1 8-Outlets PDU、144KW 120V Single-Phase ATS/Monitoring トリップライト PDUMNH15AT1 8-アウトレット PDU、144KW 120V シングルフェーズ ATS/モニタリング

Tripp Lite PDUMNH15AT1

₦886,700.00 ₦1,523,800.00 Save ₦637,100
認定パートナー
ブランド新しい
入手可能時間: 在庫あり 、発送準備が整いました。 .
  • Free Shipping
  • 1年 保証
  • 30日間の返品可能
  • カーボンニュートラル

製品の主な特長

  • 組み込みJavaフリーのHTML5ベースのLXプラットフォームインターフェースにより、常時アクセス可能、24時間365日
  • セカンダリ電源に切り替えることで、7ミリ秒未満で安定した動作を維持
  • 現場でのリアルタイムの負荷モニタリングのためのデジタル電流計が電力過負荷を防止
  • NEMA 5-15P入力を備えたデュアル12フィートのコードで、別々の電源に接続
  • GSAスケジュール購入のための連邦貿易協定法(TAA)に準拠}
₦886,700.00
無料返品
無料配送
次の順序に従ってください

時間

運ぶ

配送情報

-
+
専門家に質問する
お電話でお問い合わせください。
888.267.9566
Minimize
Info
Info Page
Reviews Top
×

×
  • 説明
  • テック・スペック
  • 返金ポリシー

Tripp Lite

PDUMNH15AT1

Tripp Lite PDUMNH15AT1 Metered Auto Transfer Switch PDU with Network Monitoring

Experience uninterrupted power distribution with the Tripp Lite PDUMNH15AT1, a 15A metered auto transfer switch PDU featuring 8 NEMA 5-15R outlets and comprehensive network monitoring capabilities. This TAA-compliant, 1U rack-mountable PDU delivers 1520W of reliable power with millisecond-fast automatic transfer switching between power sources.

Advanced Power Distribution and Monitoring Features

  • Dual 12-foot NEMA 5-15P input cords for redundant power sources
  • Real-time monitoring of voltage, frequency, and load levels
  • Built-in LX Platform network interface for remote management
  • Java-free HTML5-based WEBCARDLX for secure remote access
  • Digital load meter for preventing costly overloads
  • Environmental monitoring with temperature, humidity, and water sensors

Automatic Transfer Switch Technology

The PDU features sophisticated ATS functionality that switches to the secondary power source within 2-7 milliseconds if the primary source fails. The intelligent on-board processor continuously evaluates power quality of both sources to prevent switching to an unstable secondary source.

Installation and Mounting Options

  • Compact 1U rack-mount design (17.5" x 14.5" x 1.8")
  • Versatile wall-mounting capability
  • Durable all-metal housing construction
  • TAA and RoHS compliant for federal procurement

Package Contents

  • 8-Outlets PDU
  • Detachable C13 To NEMA 5-15P Secondary Input Cord, 12 Ft. (3.7 m)
  • Configuration Cable
  • Rack-Mounting Hardware
  • Cable Retention Kit
  • Owner's Manual
Single-Phase 15A ATS PDU Distributes and Monitors Network-Grade Power in Real Time リアルタイムでネットワークグレードの電力を配布および監視する単相15A ATS PDU。組み込みのネットワークインターフェースを介して、電圧、周波数、および負荷レベルをリアルタイムでリモート監視します。ネットワークITアプリケーション、小規模なコンピュータールーム、その他の機器ラックアプリケーション向けに理想的です。PDUMNH15AT1には、ラック機器にAC電力を供給する8つのNEMA 5-15R 120Vアウトレットが備わっています。NEMA 5-15P入力を備えた2本の12フィート(3.7メートル)の電源コードは、別々の主要および予備メイン回路、バックアップ発電機、UPSシステム、またはユーティリティ電力グリッドに接続します。 Switches from Primary to Secondary Power Source in Milliseconds プライマリソースが故障したり不安定になったりした場合、オートマチックトランスファースイッチング(ATS)により、PDUは2〜7ミリ秒以内にセカンダリソースに切り替えて、接続された機器が中断なく動作するようにします。オンボードATSプロセッサは常に両入力ソースの電力品質を評価します。セカンダリソースが利用できないか、プライマリソースよりも品質が低い場合、切り替えを防止します。 Built-In LX Platform Network Management Card Allows Remote Access 24/7 Javaを使用しないHTML5ベースのWEBCARDLXネットワークインターフェースにより、セキュアなWebブラウザ、SNMP、telnet、またはSSHを介してPDUのステータス監視とメール通知を完全なリモートアクセスできます。PowerAlertデバイスマネージャ(PADM20)の最新バージョンにより、カスタマイズ可能なダッシュボードグラフを使用して、リモート管理機能が強化されます。PADM20のアップグレードとTripp LiteのPowerAlert Element Manager(PAEM)を組み合わせることで、ファームウェアの更新チェック、デバイス構成のバックアップおよび復元など、大規模なインストールでのメンテナンス機能を拡張する強力なツールが提供されます。 Digital Load Meter Helps Prevent Potentially Expensive Overloads デジタルアンメーターは、すべての接続された機器の合計負荷を報告します。アンペア数を監視することで、過負荷による高価なダウンタイムや機器の損傷を防ぎます。新しい機器を追加しても、適切な負荷レベルを維持することで、総所有コスト(TCO)を低く抑えることができます。 Mounts into 1U of Rack Space or on a Wall 付属の取り付けハードウェアを使用して、全金属製の筐体をEIA標準19インチラックの1Uスペースに取り付けます。マウントブラケットを使用して、PDUを壁に取り付けるか、カウンターの下に固定することもできます。 TAA-Compliant for GSA Schedule Purchases PDUMNH15AT1は、連邦取引協定法(TAA)に準拠しており、GSA(一般サービス管理局)スケジュールやその他の連邦調達契約の対象となります。

Return Policy

Time to Return

Standard Return Policy

We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.

Replacement Only Return Policy

Replacement within 30 days of the delivery date.

Manufacturer Only Return Policy

Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.

Holiday Extended Return Policies

Extended Holiday Return Policy.

Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024.


Extended Holiday Replacement-Only Return Policy

Qualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.

Front view of Tripp Lite PDUMNH15AT1 PDU showing 8 outlets, digital display, and network interface

Real-Time Power Distribution with Digital Load Monitoring

The front view showcases this PDU's intelligent power management capabilities through its 8 NEMA 5-15R outlets and digital load meter display. The integrated LCD screen provides instant visibility of current draw, helping prevent circuit overloads while ensuring optimal power distribution to critical equipment. The network interface enables comprehensive remote monitoring and management.

Technical Specifications

  • 8 NEMA 5-15R outlets for flexible device connectivity
  • Digital load meter displays real-time power consumption
  • Built-in network interface for remote management

Applications

  • Data center rack power distribution
  • Network operations center equipment power management
  • Server room power monitoring and control
Close-up view of digital display and network interface on Tripp Lite PDU

High-Resolution Digital Monitoring Interface

The detailed close-up highlights the PDU's precision monitoring capabilities through its clear digital display and network management interface. The LED screen provides accurate load readings in real-time, while the network port enables comprehensive remote power monitoring and management through SNMP, web, or command-line interfaces.

Technical Specifications

  • High-visibility LED load meter display
  • Integrated WEBCARDLX network management card
  • HTML5-based remote monitoring interface

Applications

  • Remote power consumption monitoring
  • Load balancing across circuits
  • Preventive maintenance scheduling
Side view showing metal construction of Tripp Lite PDU chassis

Robust Metal Housing Construction

The PDU's durable all-metal housing is engineered for long-term reliability in demanding rack environments. The 1U form factor optimizes valuable rack space while providing secure mounting options. The sturdy construction ensures protection of internal components and reliable operation.

Technical Specifications

  • 1U rack-mount form factor
  • All-metal protective housing
  • Industrial-grade construction materials

Applications

  • High-density rack installations
  • Industrial environment deployment
  • Space-constrained equipment rooms
Angled view of PDU showing outlet arrangement and cable management features

Angled Outlet Design for Cable Management

The strategic angled outlet configuration facilitates organized cable routing while reducing cord stress. This design optimizes space utilization and maintains proper airflow within the rack. The outlet arrangement supports efficient power distribution while enabling clean cable management.

Technical Specifications

  • Angled outlet orientation for cable organization
  • Integrated cable management support
  • Space-efficient outlet placement

Applications

  • High-density cable management
  • Organized rack power distribution
  • Clean installation requirements
Rear view of PDU showing dual power inputs and configuration port

Dual Power Input Connectivity

The rear panel showcases the PDU's automatic transfer switch capabilities through dual power inputs. This design enables connection to separate power sources for enhanced reliability. The configuration port provides local access for initial setup and maintenance.

Technical Specifications

  • Dual NEMA 5-15P power inputs
  • 2-7ms automatic transfer switching
  • RS-232 configuration port

Applications

  • Redundant power source implementation
  • Critical infrastructure protection
  • High-availability installations
Installation components including mounting brackets, cables, and documentation

Complete Installation Kit Components

The comprehensive mounting kit includes all necessary hardware for various installation scenarios. The package contains rack mounting brackets, screws, cable management accessories, and detailed documentation for proper setup and configuration.

Technical Specifications

  • Universal rack mounting brackets
  • Cable retention accessories
  • Configuration cable included

Applications

  • New rack installations
  • Equipment room upgrades
  • Infrastructure expansion projects
Close-up of mounting brackets, screws and installation manual

Essential Mounting Hardware Package

The mounting hardware kit provides flexible installation options for various rack configurations. The included brackets support both rack and wall mounting scenarios, while the installation guide ensures proper setup procedures are followed.

Technical Specifications

  • Multiple mounting configuration support
  • Industrial-grade mounting hardware
  • Detailed installation documentation

Applications

  • Standard rack deployment
  • Wall-mount installations
  • Under-counter mounting scenarios
よくある質問
The Tripp Lite PDUMNH15AT1 is a single-phase 15A PDU featuring 8 NEMA 5-15R outlets, automatic transfer switching (ATS), and real-time power monitoring capabilities. It includes dual 12-foot power cords with NEMA 5-15P inputs, a built-in WEBCARDLX network interface for remote monitoring, and supports up to 1520W power rating. The unit can be mounted in 1U of rack space or wall-mounted, and includes environmental monitoring for temperature, humidity, and water.
The PDU's ATS functionality automatically switches between primary and secondary power sources within 2-7 milliseconds if the primary source fails or becomes unstable. An on-board ATS processor continuously evaluates power quality of both input sources and prevents switching if the secondary source is unavailable or of lower quality than the primary source, ensuring uninterrupted operation of connected equipment.
The PDUMNH15AT1 offers flexible mounting options: it can be installed in 1U of space in a standard 19-inch EIA rack using the included mounting hardware, or wall-mounted under a counter. The unit measures 1.8" height x 17.5" width x 14.5" depth and weighs approximately 11 pounds.
The PDU features a Java-free HTML5-based WEBCARDLX network interface that enables comprehensive remote management including status monitoring and email notifications via secure web browser, SNMP, telnet, or SSH. It supports PowerAlert Device Manager (PADM20) with customizable dashboard graphs and PowerAlert Element Manager (PAEM) for enhanced maintenance functions in large installations.
The PDU operates on 120V AC input voltage with 15A input current and supports a power rating of 1520W. It provides output voltage options of 100V AC, 120V AC, or 127V AC through its 8 NEMA 5-15R outlets. The unit includes dual NEMA 5-15P inputs for connection to separate power sources.
The PDUMNH15AT1 includes comprehensive environmental monitoring capabilities with built-in sensors for water, temperature, and humidity. These features allow users to monitor environmental conditions in the rack or data center, helping prevent equipment damage and maintain optimal operating conditions.
The package includes the 8-outlet PDU unit, a detachable C13 to NEMA 5-15P secondary input cord (12 ft/3.7m), configuration cable, rack-mounting hardware, cable retention kit, and owner's manual. All necessary components for installation and operation are provided in the package.
The PDUMNH15AT1 comes with a 2-year limited warranty and is TAA compliant, making it eligible for GSA Schedule and federal procurement contracts. It is also RoHS certified, confirming its environmental friendliness and compliance with hazardous substance restrictions.