Tripp Lite PDUMH30HVATNET PDU con commutazione 19 prese montabile su rack 2U AC 230V
Tripp Lite PDUMH30HVATNET PDU con commutazione 19 prese montabile su rack 2U AC 230V
Tripp Lite PDUMH30HVATNET
- Free Shipping
- 1 Anno Garanzia
- Resi entro 30 giorni
- Carbon Neutral: Neutro in carbonio
Caratteristiche chiave del prodotto
- Interruttore di trasferimento automatico monofase da 30A 208/240V / PDU ATS con commutazione a stato solido
- Ingressi primario e secondario separati consentono l'opzione di alimentazione ridondante per dispositivi di rete non ridondanti
- Interfaccia di rete della piattaforma LX
- Installazione a rack da 2U, 2 ingressi L6-30P, 19 prese commutate (16 C13, 2 C19, 1 L6-30R)
- Prese commutate individualmente, interfaccia di rete e monitoraggio visivo corrente, tensione e ambientale
- Conforme al Federal Trade Agreements Act (TAA) per gli acquisti del programma GSA}
Tripp Lite PDUMH30HVATNET PDU con commutazione 19 prese montabile su rack 2U AC 230V
Tripp Lite PDUMH30HVATNET
- Free Shipping
- 1 Anno Garanzia
- Resi entro 30 giorni
- Carbon Neutral: Neutro in carbonio
Caratteristiche chiave del prodotto
- Interruttore di trasferimento automatico monofase da 30A 208/240V / PDU ATS con commutazione a stato solido
- Ingressi primario e secondario separati consentono l'opzione di alimentazione ridondante per dispositivi di rete non ridondanti
- Interfaccia di rete della piattaforma LX
- Installazione a rack da 2U, 2 ingressi L6-30P, 19 prese commutate (16 C13, 2 C19, 1 L6-30R)
- Prese commutate individualmente, interfaccia di rete e monitoraggio visivo corrente, tensione e ambientale
- Conforme al Federal Trade Agreements Act (TAA) per gli acquisti del programma GSA}
Tripp Lite
PDUMH30HVATNET
Lo switch automatico ATS / switch di trasferimento automatico di Tripp Lite fornisce un'opzione di alimentazione ridondante per dispositivi di rete con un solo cavo. I cavi di ingresso duali supportano una connessione separata alle fonti di alimentazione PRIMARIA e SECONDARIA. L'ATS manterrà normalmente un'uscita continua a tutte le prese come derivato dal cavo di ingresso primario. Se la fonte di alimentazione primaria diventa instabile o fallisce del tutto, l'ATS passerà alla fonte di alimentazione secondaria fino a quando l'ingresso primario non sarà ripristinato e stabile. Il passaggio altamente affidabile a stato solido tra gli ingressi primario e secondario avviene in 1-5 millisecondi. Le caratteristiche del PDU switchato includono prese di uscita controllabili singolarmente e interfaccia di rete integrata. Il passaggio super veloce tra le fonti di alimentazione primaria e secondaria avviene entro millisecondi. La funzionalità ATS è supportata da due fonti di alimentazione AC compatibili, indipendentemente dall'angolo di fase, per supportare una varietà di applicazioni di rete di alimentazione ridondante avanzate. Consente la protezione UPS hot-swappable a prova di guasto quando utilizzata con un singolo UPS e protezione UPS completamente ridondante quando ogni cavo è collegato a un sistema UPS separato. In un ambiente a due UPS, il cavo di ingresso primario deve essere supportato da un UPS a onda sinusoidale a tempo zero. La serie Tripp Lite SmartOnline è altamente raccomandata per l'uso come UPS primario in un'applicazione a due UPS. Le configurazioni ATS che utilizzano circuiti di rete separati, generatori di backup e persino alimentazioni di rete di servizio separate sono completamente supportate. Il processore ATS integrato valuta costantemente la qualità dell'alimentazione su entrambe le fonti di ingresso per evitare il passaggio alla fonte secondaria quando non disponibile o di qualità inferiore rispetto alla fonte primaria. I LED di ingresso frontale visualizzano la disponibilità di alimentazione primaria o secondaria. Scheda di interfaccia di gestione della rete LX Platform integrata. L'interfaccia di rete basata su HTML5 della piattaforma LX senza Java consente un accesso remoto completo per il monitoraggio dello stato del PDU e le notifiche via email tramite un browser web sicuro, SNMP, telnet o SSH. Supporta auto-sensing 10/100 Mbps per una comunicazione ottimale con una rete Ethernet. I moduli opzionali EnviroSense2 (venduti separatamente) forniscono una varietà di capacità di monitoraggio ambientale. I protocolli supportati includono HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP e NTP.
Key Features
5.76kW Single-Phase ATS/Switched PDU Provides a Redundant Power Option
Tripp Lite’s PDUMH30HVATNET ATS/Switched provides all the management features of a switched PDU, plus a redundant 208/240V power option for single-corded network devices in data centers, network closets, server rooms, computer rooms and other environments requiring network-grade power. This PDU has 19 switched outlets (16 C13, 2 C19 and 1 L6-30R) and supports mounting in 2U of rack space, on a wall or under a counter.
Primary and Secondary Inputs for Power RedundancyTo provide redundant power for network devices, this PDU has dual 10 ft. (3 m) input power cords with NEMA L6-30P plugs for connection to compatible AC power sources, including separate mains circuits, backup generators and separate utility power grid feeds. Dual inputs also enable fault tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full-time sine wave UPS with zero transfer time, such as a Tripp Lite SmartOnline UPS. |
|
Switches to Secondary Power Source in MillisecondsDynamic solid-state automatic transfer switching allows the PDUMH30HVATNET to switch to the secondary source within 2–6 milliseconds if the primary source fails or becomes unstable. This ensures your connected equipment operates without interruption. A built-in processor monitors both sources and prevents switching if the secondary source is unavailable or of lower quality than the primary source. LX Platform Network Interface Provides Remote Monitoring The LX Platform network interface comes installed in the PDU, enabling full remote access for status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It is a Java-free HTML5-based interface that supports 10/100 Mbps auto-sensing for effective network communication. Optional EnviroSense2 modules (sold separately) add a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. |
|
Offers Individual Outlet Control from AnywhereAdvanced remote capabilities can help minimize downtime and reduce the frequency of on-site visits to save you time and money. Each outlet can be managed individually for load shedding, load ramping and programming of power-on/power-off sequences. Unused outlets can be disabled to prevent the connection of unauthorized equipment loads. Each outlet has an LED to confirm power on/off status. Multifunction Digital Display and Load Meter A digital display reports primary source and secondary source input power status and other information, including amps, kilowatts and voltage values. You can also monitor the load in each bank, as well as the total load, allowing you to connect equipment without overloading the PDU. |
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is a manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosures, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 95 years of quality products and service, Tripp Lite is a brand you can trust.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |