ट्रिप्लाइट PDUMH30HVATNET स्विच किया हुआ PDU 19-आउटलेट 2U रैक-माउंट करने योग्य 230V एसी

Front view of Tripp Lite PDUMH30HVATNET PDU showing digital display, output breaker banks, and network management ports-alternate-image1
Rear view of PDU showing 19 power outlets arranged in three banks-alternate-image2
Side view of 2U rack-mount PDU showing mounting holes and construction-alternate-image3
Detailed view of PDU outlet configuration and power distribution system-alternate-image4
Close-up of USB cable connection for PDU management-alternate-image5
Front panel view highlighting digital display and control interface-alternate-image6
Close-up of PDU's LED display showing power monitoring metrics-alternate-image7
Side view showing PDU's industrial construction and cooling design-alternate-image8
Close-up of dual NEMA L6-30P power input connectors-alternate-image9
Installation kit components including mounting brackets, cable ties, and documentation-alternate-image10

ट्रिप्लाइट PDUMH30HVATNET स्विच किया हुआ PDU 19-आउटलेट 2U रैक-माउंट करने योग्य 230V एसी

Tripp Lite PDUMH30HVATNET

₦1,820,900.00 ₦3,190,500.00 Save ₦1,369,600
Authorized Partner
Brand New
Availability: In stock , ready to be shipped .
  • Free Shipping
  • 1 Year Warranty
  • 30 Day Returns
  • Carbon Neutral

Product Key Features

  • सिंगल फेज 30A 208/240V ऑटो ट्रांसफर स्विच / एटीएस पीडीयू सॉलिड स्टेट स्विचिंग के साथ
  • अलग प्राइमरी और सेकंडरी इनपुट गैर-रेडंडेंट नेटवर्क डिवाइस के लिए रेडंडेंट-पावर विकल्प सक्षम करते हैं
  • LX प्लेटफॉर्म नेटवर्क इंटरफेस
  • 2U रैकमाउंट, 2 L6-30P इनपुट, 19 स्विच किए गए आउटलेट (16 C13, 2 C19, 1 L6-30R)
  • व्यक्तिगत रूप से स्विच किए गए आउटलेट, नेटवर्क इंटरफेस और दृश्य वर्तमान, वोल्टेज और पर्यावरणीय निगरानी
  • जीएसए शेड्यूल खरीद के लिए संघीय व्यापार समझौता अधिनियम (टीएए) के साथ अनुपालन
₦1,820,900.00
FREE Returns
FREE Delivery
Order in the next

hrs

mins

to be delivered on

Shipping information

-
+
Ask Our Experts
Call Us Now
888.267.9566
Minimize
Info
Info Page
Reviews Top
×

×
  • Description
  • Tech Specs
  • Refund Policy

Tripp Lite

PDUMH30HVATNET

Tripp Lite PDUMH30HVATNET 230V Switched PDU with Auto Transfer Switch

The Tripp Lite PDUMH30HVATNET is a 2U rack-mountable switched PDU featuring 19 outlets and advanced Auto Transfer Switch (ATS) functionality for mission-critical network devices. Operating at 230V AC, this intelligent PDU provides redundant power options with millisecond-fast switching capabilities and comprehensive network management features.

Advanced Power Distribution and Redundancy Features

This switched PDU comes equipped with dual NEMA L6-30P inputs for connecting to separate PRIMARY and SECONDARY power sources. The ATS functionality ensures continuous power delivery through automatic switching between sources in just 1-5 milliseconds, making it ideal for fault-tolerant and redundant power configurations.

Outlet Configuration

  • 16 IEC 60320 C13 outlets for standard device connections
  • 2 IEC 60320 C19 outlets for high-amperage devices
  • 1 NEMA L6-30R outlet for additional power distribution

Network Management and Monitoring Capabilities

Features an integrated LX Platform network interface with HTML5-based management system supporting:

  • Secure protocols: HTTP, HTTPS, SMTP, SNMPv1/v2/v3
  • Remote access via telnet, SSH, and FTP
  • 10/100 Mbps auto-sensing Ethernet connectivity
  • Compatible with optional EnviroSense2 monitoring modules

Installation and Compliance

Designed for professional data center environments, this PDU features:

  • 2U horizontal rack-mounting configuration
  • TAA compliance for government installations
  • RoHS environmental certification
  • 2-year limited warranty coverage
Key Feature: Highly reliable solid-state switching between power sources occurs within 1-5 milliseconds, ensuring uninterrupted operation of connected equipment.

Return Policy

Time to Return

Standard Return Policy

We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.

Replacement Only Return Policy

Replacement within 30 days of the delivery date.

Manufacturer Only Return Policy

Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.

Holiday Extended Return Policies

Extended Holiday Return Policy.

Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024.


Extended Holiday Replacement-Only Return Policy

Qualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.

Front view of Tripp Lite PDUMH30HVATNET PDU showing digital display, output breaker banks, and network management ports

Intelligent Power Management with Digital Display

The front panel features dual output breaker banks and an intuitive digital interface for real-time monitoring. The integrated LX Platform network management interface enables comprehensive power oversight through the digital display and remote access capabilities, putting precise control at your fingertips.

Technical Specifications

  • Digital monitoring interface with LED display
  • Dual output breaker banks for load management
  • Integrated network management card with Ethernet port

Applications

  • Data center power distribution monitoring
  • Remote power management for server rooms
  • Critical infrastructure power control
Rear view of PDU showing 19 power outlets arranged in three banks

High-Density Power Distribution with 19 Outlets

The rear panel provides 19 strategically arranged outlets including IEC C13, C19 and NEMA configurations. This thoughtful layout maximizes space efficiency while ensuring adequate power distribution for various IT equipment needs. The organized outlet arrangement facilitates clean cable management and optimal airflow.

Technical Specifications

  • 16 IEC C13 outlets for standard devices
  • 2 IEC C19 outlets for high-amperage equipment
  • 1 NEMA L6-30R outlet for specialized hardware

Applications

  • High-density server rack power distribution
  • Mixed IT equipment power management
  • Scalable data center power solutions
Side view of 2U rack-mount PDU showing mounting holes and construction

Robust 2U Rack-Mount Design

The durable metal housing is engineered for 2U rack installation, offering excellent thermal management and structural integrity. The sleek black finish complements modern rack environments while providing reliable protection for internal components.

Technical Specifications

  • 2U form factor for standard 19-inch racks
  • Heavy-duty metal construction
  • Integrated mounting points

Applications

  • Standard rack integration
  • High-reliability data center deployment
  • Professional IT infrastructure installation
Detailed view of PDU outlet configuration and power distribution system

Advanced Power Distribution Architecture

This view highlights the PDU's efficient outlet layout and power distribution design. The organized bank structure enables systematic power management while supporting high-density equipment deployments. The robust chassis ensures reliable operation in demanding data center environments.

Technical Specifications

  • Organized three-bank outlet configuration
  • 230V AC power distribution
  • Enterprise-grade build quality

Applications

  • Enterprise data center deployment
  • High-availability power distribution
  • Mission-critical infrastructure support
Close-up of USB cable connection for PDU management

USB Connectivity for Enhanced Management

The USB interface enables direct connection to management systems for configuration and monitoring. This dedicated port provides an additional layer of control and management capabilities, supporting comprehensive power infrastructure oversight.

Technical Specifications

  • USB Type-A to Type-B connection
  • Direct management interface
  • Plug-and-play configuration support

Applications

  • Local PDU configuration
  • System integration and monitoring
  • Management software connectivity
Front panel view highlighting digital display and control interface

Intelligent Control Interface

The front panel showcases the PDU's comprehensive monitoring capabilities with clear digital readouts and status indicators. The interface provides essential power metrics and system status at a glance, enabling proactive power management.

Technical Specifications

  • Multi-function digital display
  • Status LED indicators
  • Network management ports

Applications

  • Real-time power monitoring
  • System status verification
  • Remote management access
Close-up of PDU's LED display showing power monitoring metrics

Precision Monitoring Display

The detailed LED display provides critical power metrics including voltage, current, and power consumption. This real-time monitoring capability enables precise power management and early detection of potential issues.

Technical Specifications

  • Multi-metric digital readout
  • Power and temperature monitoring
  • Active input source indication

Applications

  • Power consumption tracking
  • Environmental monitoring
  • Load balancing verification
Side view showing PDU's industrial construction and cooling design

Industrial-Grade Construction

The PDU's solid construction ensures reliable operation in demanding environments. The robust chassis design provides excellent protection for internal components while facilitating proper cooling and ventilation.

Technical Specifications

  • Heavy-duty metal housing
  • Passive cooling design
  • Rack-optimized form factor

Applications

  • High-reliability installations
  • Industrial environment deployment
  • Long-term infrastructure solutions
Close-up of dual NEMA L6-30P power input connectors

Dual Input Power Connections

Features redundant NEMA L6-30P inputs for power source diversity and reliability. The gold-plated connectors ensure optimal electrical contact and long-term durability, supporting mission-critical power delivery.

Technical Specifications

  • NEMA L6-30P connector standard
  • Gold-plated contact surfaces
  • 30A power handling capacity

Applications

  • Redundant power source connection
  • High-availability configurations
  • Critical infrastructure support
Installation kit components including mounting brackets, cable ties, and documentation

Complete Installation Kit

Includes all necessary mounting hardware and cable management accessories for professional installation. The comprehensive kit ensures proper setup and organization of power infrastructure in rack environments.

Technical Specifications

  • Rack mounting brackets and hardware
  • Cable management accessories
  • Installation documentation

Applications

  • Professional rack installation
  • Cable organization setup
  • Infrastructure deployment
FAQ
The Tripp Lite PDUMH30HVATNET is a 2U rack-mountable Switched PDU with 19 outlets operating at 230V AC. Key features include automatic transfer switch (ATS) functionality with dual input cords, 1-5 millisecond switchover time between power sources, individually controllable outlets, and a built-in LX Platform network management interface. It offers 16 IEC 60320 C13 outlets, 2 IEC 60320 C19 outlets, and 1 NEMA L6-30R outlet, making it highly versatile for various equipment connections.
The ATS functionality maintains continuous power output from the primary input source and automatically switches to the secondary source if the primary becomes unstable or fails. The switchover occurs within 1-5 milliseconds using highly reliable solid-state switching. The PDU's processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source if it's unavailable or of lower quality. This system works with any two compatible AC power sources, regardless of phase angle, supporting various redundant power configurations.
The PDU features a built-in LX Platform network management interface with HTML5-based interface supporting multiple protocols including HTTP, HTTPS, SMTP, SNMPv1/v2/v3, telnet, SSH, FTP, DHCP, and NTP. It enables full remote access for PDU status monitoring and email notifications via secure web browser, with 10/100 Mbps auto-sensing for optimal Ethernet network communication. The system is Java-free and compatible with optional EnviroSense2 modules for environmental monitoring.
The PDU features a total of 19 outlets with the following configuration: 16 IEC 60320 C13 outlets, 2 IEC 60320 C19 outlets, and 1 NEMA L6-30R outlet. Input connections are provided through 2 NEMA L6-30P plugs, supporting the dual-input ATS functionality. All outlets are individually controllable through the network management interface.
This PDU is designed for horizontal rack mounting and occupies 2U of rack space. It's specifically designed to be rack-mountable in a standard equipment rack, making it ideal for data center and network closet installations. The horizontal orientation ensures efficient use of rack space while providing easy access to all outlets and management features.
The Tripp Lite PDUMH30HVATNET comes with a 2-year limited warranty. It is TAA compliant and environmentally friendly with RoHS certification. The product is manufactured in Taiwan and meets various regulatory and environmental standards, ensuring reliability and compliance with government and industry requirements.
The PDU supports both fault-tolerant hot-swappable UPS protection with a single UPS and fully redundant protection when each cord connects to a separate UPS system. For dual-UPS setups, the primary input requires a full-time sine wave UPS with zero transfer time (Tripp Lite SmartOnline series recommended). The system also supports configurations using separate mains circuits, backup generators, or separate utility power grid feeds.
The PDU provides comprehensive monitoring through its LX Platform interface, including front panel LED indicators showing primary or secondary power availability. Users can access real-time status monitoring through the web interface, receive email notifications, and utilize SNMP monitoring. The system supports optional EnviroSense2 modules for additional environmental monitoring capabilities, and offers multiple secure access methods including HTTPS, SSH, and telnet.

Accessories

Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart
Add to cart

Recently Viewed Products