Tripp Lite PDUMNV30HV2LX 42-Outlet PDU, Monitored, 5.8KW Single-Phase Power Distribution Unit
Tripp Lite PDUMNV30HV2LX 42-Outlet PDU, Monitored, 5.8KW Single-Phase Power Distribution Unit
Tripp Lite PDUMNV30HV2LX
- Free Shipping
- 2 Year Warranty
- 30 Day Returns
- Carbon Neutral
Product Key Features
- 5/5.8kW 208/240V single-phase monitored 0U PDU
- 42 outlets-36 C13, 6 C19-with plug-lock insert sleeves
- Built-in Java-free LX Platform interface for remote access 24/7
- Digital ammeter for on-site load monitoring in real time
- NEMA L6-30P input with 10 ft. AC power cord
hrs
mins
Shipping information
Tripp Lite PDUMNV30HV2LX 42-Outlet PDU, Monitored, 5.8KW Single-Phase Power Distribution Unit
Tripp Lite PDUMNV30HV2LX
- Free Shipping
- 2 Year Warranty
- 30 Day Returns
- Carbon Neutral
hrs
mins
Shipping information
Product Key Features
- 5/5.8kW 208/240V single-phase monitored 0U PDU
- 42 outlets-36 C13, 6 C19-with plug-lock insert sleeves
- Built-in Java-free LX Platform interface for remote access 24/7
- Digital ammeter for on-site load monitoring in real time
- NEMA L6-30P input with 10 ft. AC power cord
Tripp Lite
PDUMNV30HV2LX
The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
Provides Advanced Network Monitoring Capabilities
Featuring a built-in, Java-free, HTML5-based LX Platform interface, the PDUMNV30HV2LX provides remote power monitoring via a secure network or Web browser. When used with optional EnviroSense2 environmental sensor modules (sold separately), it can also perform temperature/humidity and dry contact monitoring, providing IT personnel with enhanced oversight of facility power and environmental conditions. Up to three EnviroSense2 modules can be daisy-chained together. The PDUMNV30HV2LX supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts via email or SNMP traps can be configured to warn against potential overload, power loss and downtime. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration support provides the ability to have network settings automatically assigned or manually assigned via a permanent IP address.
Product Specifications
Distributes and Monitors Single-Phase 208/240V Power with No Java Required
Tripp Lite's PDUMNV30HV2LX 5/5.8 kW Single-Phase Monitored PDU is an efficient, cost-effective power distribution solution with remote monitoring capabilities. Its 42 outlets (36 C13 and 6 C19) are organized into two separate breakered load banks that can be monitored remotely or locally via the unit’s digital ammeter. Designed for users who prefer a Java-free interface, this PDU uses 208/240V single-phase input to distribute 200-240V single-phase output. The 10 ft. cord has a NEMA L6-30P plug.
Supports Real-Time Load and Power Status Monitoring
The PDUMNV30HV2LX is equipped with a digital ammeter that allows IT personnel to monitor the PDU’s total load in real time. This meter helps ensure the PDU is used at maximum capacity with no danger of overload. Outlets are split into two load banks; the ammeter reports current for each bank, as well as for the total connected PDU load.
Integrates Easily Into Your Existing Infrastructure
This PDU mounts vertically in a standard rack enclosure, occupying 0U in the rack, freeing up space for other equipment and promoting efficient airflow. It also supports toolless button-mount installation. An included PDUMVROTATEBRKT kit allows the PDU to be mounted with rear-facing outlets for improved airflow and equipment access. Plug-lock insert sleeves prevent cables from becoming disconnected accidentally.
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is a leading manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosures, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 95 years of quality products and service, Tripp Lite is a brand you can trust.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |