Tripp Lite PDUNVR30HVLX: 5.8kW Monitored PDU with Advanced Network Management
The Tripp Lite PDUNVR30HVLX is a high-performance 208/240V monitored PDU featuring 24 outlets (20 C13 and 4 C19) with advanced power monitoring capabilities. This 0U vertical PDU delivers 5.8kW single-phase power distribution with real-time remote monitoring through SNMP, Telnet, and SSH protocols, making it ideal for data centers, computer rooms, and high-density network environments.
Advanced Power Monitoring and Distribution Features
Experience precise power management with 1% billing-grade consumption monitoring for each outlet. The PDU provides comprehensive monitoring of:
- Per-outlet power consumption metrics
- Input current monitoring up to 30A
- Voltage monitoring for 208/240V operations
- Dual breakered load banks for enhanced power distribution
Key Feature: Built-in LX Platform network interface enables HTML5-based remote management with full 10/100/1000 Mbps auto-sensing capability.
Intelligent Network Management and Security
The PDUNVR30HVLX comes equipped with advanced network management features including:
- Java-free HTML5-based monitoring interface
- SNMP, Telnet, and SSH protocol support
- Auto Probe functionality for autonomous PDU management
- Email notifications for status updates and alerts
- Compatible with optional EnviroSense2 modules for environmental monitoring
Installation and Physical Specifications
The 70-inch 0U PDU features:
- Toolless vertical mounting design
- PDUMVROTATEBRKT kit for flexible outlet orientation
- 10-foot power cord with NEMA L6-30P input
- Compact dimensions: 70"H x 2.2"W x 2.6"D
- TAA-compliant for GSA Schedule purchases
Package Contents
- PDUNVR30HVLX 24-Outlets PDU
- Built-in LX Platform Interface
- Configuration Cable
- 20 x C13 Plug-Lock Inserts
- 4 x C19 Plug-Lock Inserts
- Rack-Mounting Hardware
- PDUMVROTATEBRKT Mounting Bracket Accessory
- Owner's Manual
Warranty: Backed by Tripp Lite's 2-year limited warranty for reliable performance and peace of mind.
5.8kW Single-Phase PDU Distributes and Monitors Network-Grade Power
This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your small-to-mid-sized data center, computer room or high-density network closet, the PDUNVR30HVLX features 20 C13 and 4 C19 208/240V outlets in two breakered load banks, which distribute AC power to rack equipment. Advanced network power monitoring provides 1% billing-grade power consumption data for devices connected to each outlet.
Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real Time
Not only can you remotely monitor voltage and frequency, but the PDUNVR30HVLX also allows metering of input current, as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks, as well as compare power usage among various devices.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities.
Auto Probe Allows Autonomous PDU Management
The LX Platform interface allows use of Tripp Lite's IP-based Auto Probe feature, which ensures continuous network uptime by communicating with other network devices. If communication is lost, Auto Probe autonomously performs one or more user-configurable actions that help you return the network devices to an operational state, including email notifications. The innovative Auto Probe is especially ideal for ATMs, retail kiosks, digital signage, edge computing and PC gaming centers.
Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the load for each outlet bank separately and the total connected load. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment.
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A 10-foot cord with a NEMA L6-30P input connects the PDU to a compatible AC power source, such as a generator or protected UPS.
TAA-Compliant for GSA Schedule Purchases
The PDUNVR30HVLX is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.