Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP

Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP

Tripp Lite PDU3XEVSRHWA 24-Outlets PDU, 28.8KW 3-Phase Switched, IPv4, IPv6, HTTP, HTTPS, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP

Tripp Lite PDU3XEVSRHWA

¥12,917.00 ¥17,368.00 Save ¥4,451
Authorized Partner
Brand New
Availability: Sold out!
  • Free Shipping
  • 2 Year Warranty
  • 30 Day Returns
  • Carbon Neutral

Input Voltage:

  • 230VAC
  • 380VAC,400VAC,415VAC

Output Voltage:

  • 120VAC,208VAC
  • 220VAC,230VAC,240VAC

Receptacle Detail:

  • 21xNEMA5-15/20R
  • 12xIEC60320C19

Product Key Features

  • 12 C13 and 12 C19 220/230/240V outlets distribute clean power to connected equipment
  • Built-in Java-free HTML5-based LX Platform interface allows you 24/7 remote access
  • Remote power monitoring and control reduces on-site visits and maintenance costs
  • Hardwire (3P+N+E) 380/400/415V 3-phase input connects to compatible AC source
  • Color touchscreen LCD provides current levels, environmental data and network info
¥12,917.00
FREE Returns
-
+
Notify me when available
Ask Our Experts
Call Us Now
888.267.9566
Minimize
Info
Info Page
Reviews Top
×

×
  • Description
  • Tech Specs
  • Refund Policy

Tripp Lite

PDU3XEVSRHWA

0U PDU Distributes, Monitors and Manages Network-Grade Power

Recommended for data centers, server rooms and network closets, this switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can efficiently manage network power consumption data per phase, per outlet and per load bank, detect imbalanced PDU loading and remotely reboot locked network items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance.

24 Outlets Dispense AC Power

During normal operation, 24 individually controllable outlets-12 C13 and 12 C19-distribute AC power to connected equipment. Each 220/230/240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets are split into six separately breakered load banks that can be individually monitored to ensure proper load levels and prevent downtime due to overload related breaker trips. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.

Built-In LX Platform Network Management Card Allows Remote Access 24/7

The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.

Color Touchscreen LCD Offers Important Data at a Glance

An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the switched PDU via mobile device. If an EnviroSense2 module is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.

Easy to Install Vertically in an EIA-Standard 19 in. Rack

The 0U PDU mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. Hardwire 380/400/415V input connects the PDU to a compatible AC power source, generator or protected UPS.

TAA-Compliant for GSA Schedule Purchases

The PDU3XEVSRHWA is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.

2-Year Warranty

The PDU3XEVSRHWA is backed by a 2-year warranty, ensuring reliability and performance.

Return Policy

Time to Return

Standard Return Policy

We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.

Replacement Only Return Policy

Replacement within 30 days of the delivery date.

Manufacturer Only Return Policy

Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.

Holiday Extended Return Policies

Extended Holiday Return Policy.

Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024.


Extended Holiday Replacement-Only Return Policy

Qualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.

FAQ
The Tripp Lite 3-Phase Switched PDU has a power rating of 28.8KW, providing ample power for your equipment.
Yes, you can remotely manage and control the Tripp Lite 3-Phase Switched PDU through various management interfaces such as IPv4, IPv6, HTTP, HTTPS, SNMP, telnet, and SSH.
Yes, the Tripp Lite 3-Phase Switched PDU is equipped with overload protection to safeguard your equipment from power surges and overloads.
This PDU features a combination of IEC 60320 C19 and IEC 60320 C13 receptacles, providing flexibility for different types of equipment.
Yes, the Tripp Lite 3-Phase Switched PDU is rack-mountable, making it easy to integrate into your existing rack setup.
Yes, the Tripp Lite 3-Phase Switched PDU is RoHS compliant, ensuring it meets environmental standards for hazardous substances.