Tripp Lite PDU3EVSR6L2130 30-Outlet PDU 10 kW Leistungsbewertung Dreiphasen- Schalt- Überlastschutz
Tripp Lite PDU3EVSR6L2130 30-Outlet PDU 10 kW Leistungsbewertung Dreiphasen- Schalt- Überlastschutz
Tripp Lite by Eaton PDU3EVSR6L2130
- Free Shipping
- 1 Jahr. Garantie
- 30-tägige Rückgabe
- Klimaneutral
Produkthauptmerkmale
- 10kW 200/208/240V 3-Phasen-Schaltpanel 0U PDU
- 10kW 200/208/240V 3-Phasen-Schaltpanel 0U PDU
- 30 einzeln steuerbare Steckdosen-24 C13, 6 C19
- 30 einzeln steuerbare Steckdosen-24 C13, 6 C19
- Eingebaute LX Platform-Schnittstelle für Fernzugriff
Stunden
Minuten
Versandinformationen
Tripp Lite by Eaton
PDU3EVSR6L2130-UsedLikeNew
Sed bibendum ullamcorper efficitur
Aenean mollis id sem quis porttitor. Aliquam dignissim magna vel enim dignissim vehicula. Maecenas efficitur urna vitae egestas congue. Nam semper molestie velit, ut congue nulla dignissim quis. Pellentesque habitant morbi tristique senectus et netus et malesuada fames ac turpis egestas. Suspendisse efficitur ante.
10kW 3-Phase Switched PDU with LX Platform Interface and Touchscreen LCD
Tripp Lite’s PDU3EVSR6L2130 distributes, monitors and manages 200/208/240V power to connected rack equipment in data centers, network closets, server rooms, computer rooms and other applications requiring network-grade power. Its built-in network interface allows real-time remote monitoring of voltage, frequency and load levels to prevent overloads that cause expensive downtime. The PDU features 30 switched outlets (24 C13 and six C19) in three breakered load banks. A six-foot power cord with NEMA L21-30P plug connects the PDU to a compatible AC power source, generator or protected UPS system.
Cursus Sapien Ut
Built-In LX Platform Network Management Interface
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
Color Touchscreen LCD A color
touchscreen LCD lets you toggle between menus to monitor input current level per phase, output current per load bank and per outlet with ±1% billing-grade accuracy, environmental sensor data and network information. The LCD also generates a unique QR code to allow access to the free downloadable PowerAlert® Device Manager through a mobile device. Full access is available by logging into PowerAlert via web browser as a user with read/write credentials.
Remote Individual Outlet Control
For a higher level of network power control, the 24 C13 and six C19 outlets can be individually controlled in real time. These controllable outlets enable power management tasks, including load shedding, load ramping, programming power-on and power-off sequences, and rebooting of locked-up network devices, to be performed remotely. Unused outlets can be disabled to prevent the connection of unauthorized equipment loads. Each outlet has an LED that illuminates to confirm power on/off status.
Cursus Sapien Ut
Optimized for Demanding Applications
The all-metal case is designed to endure in demanding IT and industrial environments. The locking NEMA L21-30P plug and included plug-lock insert sleeves for the outlets help prevent the PDU and its connected equipment from becoming accidentally disconnected. Real-time clock backup maintains the time of day and date, even if the PDU is shut down and unpowered.
Versatile Installation Options
The PDU3EVSR6L2130 mounts vertically in 0U of space in EIA-standard 19-inch 2-post and 4-post racks using the included toolless mounting buttons or rack-mounting brackets. You can install the PDU with outlets facing either the front or rear, whichever direction offers better airflow or equipment access. Upgradable Firmware To support any future product enhancements, the PDU’s firmware can be manually upgraded.
TAA-Compliant for GSA Schedule Purchases
The PDU3EVSR6L2130 is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |