Tripp Lite PDUMH30HVATNET Switched PDU 19-Outlets 2U Rack-mountable 230V AC Tripp Lite PDUMH30HVATNET Skiftet PDU 19-Stikkontakter 2U Rack-monterbar 230V AC
Tripp Lite PDUMH30HVATNET Switched PDU 19-Outlets 2U Rack-mountable 230V AC Tripp Lite PDUMH30HVATNET Skiftet PDU 19-Stikkontakter 2U Rack-monterbar 230V AC
Tripp Lite PDUMH30HVATNET
- Free Shipping
- 1 År Garanti
- 30 dages returret
- Kulstofneutral.
Produktets nøglefunktioner
- Enfase 30A 208/240V automatisk transfer switch / ATS PDU med solid state switching
- Separate primære og sekundære indgange muliggør redundant strømoption for ikke-redundante netværksenheder
- LX Platform netværksinterface
- 2U rackmontering, 2 L6-30P indgange, 19 styrede udtag (16 C13, 2 C19, 1 L6-30R)
- Individuelt styrede udtag, netværksinterface og visuel overvågning af strøm, spænding og miljøforhold
- Overholder den føderale lov om handelsaftaler (TAA) for GSA schedule køb
timer
minutter
Forsendelsesoplysninger
Tripp Lite
PDUMH30HVATNET
Tripp Lite Switched ATS / Auto Transfer Switch giver en redundant strømmulighed for enkeltkablede netværksenheder. Dobbelt inputkabler understøtter separat tilslutning til PRIMÆR og SEKUNDÆR strømkilder. ATS vil normalt opretholde kontinuerlig output til alle stikkontakter som afledt fra det primære inputkabel. Hvis den primære strømkilde bliver ustabil eller fejler helt, skifter ATS over til den sekundære strømkilde, indtil den primære input er genoprettet og stabil. Meget pålidelig solid-state omskiftning mellem primære og sekundære input sker inden for 1-5 millisekunder. Switched PDU-funktioner inkluderer individuelt kontrollerbare outputstik og indbygget netværksinterface. Superhurtig omskiftning mellem primære og sekundære strømkilder sker inden for millisekunder. ATS-funktionalitet understøttes af ethvert to kompatible AC-strømkilder, uanset fasevinkel, for at støtte en række avancerede redundante strømnetværksapplikationer. Muliggør fejltolerant hot-swappable UPS-beskyttelse, når den bruges med en enkelt UPS og fuldt redundant UPS-beskyttelse, når hver ledning er tilsluttet et separat UPS-system. I et to-UPS-miljø skal det primære inputkabel understøttes af en fuldtids sinuskurve UPS med nul transfer tid. Tripp Lite SmartOnline-serien anbefales stærkt til brug som den primære UPS i en to-UPS-anvendelse. ATS-konfigurationer, der bruger separate hovedkredsløb, backup-generatorer og endda separate forsyningsnetværk, understøttes fuldt ud. Den indbyggede ATS-processor evaluerer konstant strømkvaliteten på begge inputkilder for at forhindre overførsel til den sekundære kilde, når den ikke er tilgængelig eller af lavere kvalitet end den primære kilde. Forreste input LED'er viser tilgængeligheden af primær eller sekundær strøm. Indbygget LX Platform netværksadministrationsinterfacekort. Det Java-frie LX Platform HTML5-baserede netværksinterface muliggør fuld fjernadgang til PDU-statusovervågning og e-mail-notifikationer via sikker webbrowser, SNMP, telnet eller SSH. Det understøtter 10/100 Mbps auto-sensing for optimal kommunikation med et Ethernet-netværk. Valgfri EnviroSense2-moduler (sælges separat) tilbyder en række miljøovervågningsmuligheder. Understøttede protokoller inkluderer HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP og NTP.
Key Features
5.76kW Single-Phase ATS/Switched PDU Provides a Redundant Power Option
Tripp Lite’s PDUMH30HVATNET ATS/Switched provides all the management features of a switched PDU, plus a redundant 208/240V power option for single-corded network devices in data centers, network closets, server rooms, computer rooms and other environments requiring network-grade power. This PDU has 19 switched outlets (16 C13, 2 C19 and 1 L6-30R) and supports mounting in 2U of rack space, on a wall or under a counter.
Primary and Secondary Inputs for Power RedundancyTo provide redundant power for network devices, this PDU has dual 10 ft. (3 m) input power cords with NEMA L6-30P plugs for connection to compatible AC power sources, including separate mains circuits, backup generators and separate utility power grid feeds. Dual inputs also enable fault tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full-time sine wave UPS with zero transfer time, such as a Tripp Lite SmartOnline UPS. |
|
Switches to Secondary Power Source in MillisecondsDynamic solid-state automatic transfer switching allows the PDUMH30HVATNET to switch to the secondary source within 2–6 milliseconds if the primary source fails or becomes unstable. This ensures your connected equipment operates without interruption. A built-in processor monitors both sources and prevents switching if the secondary source is unavailable or of lower quality than the primary source. LX Platform Network Interface Provides Remote Monitoring The LX Platform network interface comes installed in the PDU, enabling full remote access for status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It is a Java-free HTML5-based interface that supports 10/100 Mbps auto-sensing for effective network communication. Optional EnviroSense2 modules (sold separately) add a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. |
|
Offers Individual Outlet Control from AnywhereAdvanced remote capabilities can help minimize downtime and reduce the frequency of on-site visits to save you time and money. Each outlet can be managed individually for load shedding, load ramping and programming of power-on/power-off sequences. Unused outlets can be disabled to prevent the connection of unauthorized equipment loads. Each outlet has an LED to confirm power on/off status. Multifunction Digital Display and Load Meter A digital display reports primary source and secondary source input power status and other information, including amps, kilowatts and voltage values. You can also monitor the load in each bank, as well as the total load, allowing you to connect equipment without overloading the PDU. |
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is a manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosures, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 95 years of quality products and service, Tripp Lite is a brand you can trust.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |