Tripp Lite Metered PDUMV30HV2 48-Outlet PDU 230V AC 5800W Tripp Lite Målt PDUMV30HV2 48-Outlet PDU 230V AC 5800W

Full-length view of Tripp Lite PDUMV30HV2 PDU showing 48 outlet arrangement and metered display-alternate-image1
Close-up of PDU features showing digital ammeter display, circuit breaker, and outlet cluster-alternate-image2
Detailed view of C13 outlets on PDU showing construction quality-alternate-image3
Close-up view of multiple C13 outlets showing spacing and arrangement-alternate-image4
Close-up of PDU circuit breaker showing ON/OFF switch and labeling-alternate-image5
Detailed view of PDU digital amperage display with directional indicators-alternate-image6
Demonstration of PDU mounting system with button mount feature-alternate-image7
Close-up of NEMA L6-30P locking power plug-alternate-image8
Layout of PDU installation kit components including mounting hardware and plug locks-alternate-image9

Tripp Lite Metered PDUMV30HV2 48-Outlet PDU 230V AC 5800W Tripp Lite Målt PDUMV30HV2 48-Outlet PDU 230V AC 5800W

Tripp Lite PDUMV30HV2

$445.49 $743.49 Save $298
Autoriseret partner.
Helt ny
Tilgængelighed: På lager , klar til at blive sendt .
  • Free Shipping
  • 1 År Garanti
  • 30 dages returret
  • Kulstofneutral.

Produktets nøglefunktioner

  • Ideel til serverrum, netværksskabe og datacentre
  • Dobbelt belastningsbanker med 24 udtag hver (4 C19 og 20 C13)
  • Dedikerede 20A sikringer beskytter udgangen
  • NEMA L6-30P indgangsstik med 10-fods (3 m) ledning
  • Klar til øjeblikkelig værktøjsfri 0U installation
$445.49
GRATIS retur
GRATIS levering
Bestil i næste

timer

minutter

at blive leveret på

Forsendelsesoplysninger

-
+
Spørg vores eksperter.
Ring til os nu.
888.267.9566
Minimize
Info
Info Page
Reviews Top
×

×

Frequently bought together

Tripp Lite Metered PDUMV30HV2 48-Outlet PDU 230V AC 5800W Tripp Lite Målt PDUMV30HV2 48-Outlet PDU 230V AC 5800W

This item: Tripp Lite Metered PDUMV30HV2 48-Outlet PDU 230V AC 5800W...

$445.49

Total price: $445.49
  • Beskrivelse
  • Tekniske specifikationer
  • Refusionspolitik

Tripp Lite

PDUMV30HV2

Tripp Lite Metered PDUMV30HV2 48-Outlet PDU - Professional Power Distribution for High-Density Rack Environments

The Tripp Lite PDUMV30HV2 is a high-capacity 230V AC power distribution unit delivering 5800W of reliable power through 48 outlets. This 70-inch vertical mount PDU features dual load banks with real-time digital monitoring, making it ideal for mission-critical server rooms and data centers requiring precise power management.

Advanced Power Distribution Features

  • Dual load banks with 24 outlets each (4 C19 and 20 C13 per bank)
  • Digital ammeters for real-time current monitoring
  • 30A 208/240V single-phase power distribution
  • Color-coded outlets and circuit breakers for easy identification
  • NEMA L6-30P input plug with 10-foot cord

Professional-Grade Power Management

Each load bank features dedicated 20A circuit breakers with special guards to prevent accidental tripping. The unit supports balanced load distribution and includes plug-lock inserts for secure component connections. The 0U vertical mounting design optimizes rack space utilization.

Technical Specifications

  • Total Power Capacity: 5800W
  • Input/Output Voltage: 230V AC
  • Dimensions: 70"H x 2.2"W x 2.5"D
  • Weight: 12.35 lb
  • TAA Compliant and RoHS Certified

Package Contents

  • PDUMV30HV2 48-Outlet PDU
  • Plug-lock inserts (8 C20, 40 C13)
  • Spare installation buttons, 2.9mm/4.6 mm
  • Ground screw
  • Mounting hardware
  • Owner's Manual

Return Policy

Time to Return

Standard Return Policy

We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.

Replacement Only Return Policy

Replacement within 30 days of the delivery date.

Manufacturer Only Return Policy

Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.

Holiday Extended Return Policies

Extended Holiday Return Policy.

Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024.


Extended Holiday Replacement-Only Return Policy

Qualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.

Full-length view of Tripp Lite PDUMV30HV2 PDU showing 48 outlet arrangement and metered display

High-Density Power Distribution with 48 Outlets

The 70-inch vertical PDU features an efficient arrangement of 48 outlets split between two load banks. Each bank contains 24 outlets (20 C13 and 4 C19) strategically positioned for optimal cable management and equipment access. The sleek, space-saving design maximizes power distribution while minimizing rack space usage.

Technical Specifications

  • 70-inch vertical form factor for 0U mounting
  • 48 total outlets (40 C13, 8 C19)
  • 5.8kW total power capacity at 230V

Applications

  • Data center rack power distribution
  • Server room equipment deployment
  • Network infrastructure power management
Close-up of PDU features showing digital ammeter display, circuit breaker, and outlet cluster

Real-Time Load Monitoring with Digital Display

Monitor power consumption with precision using the integrated digital ammeter display. The clear LED readout shows real-time load levels for each bank, enabling proactive load balancing and preventing circuit overloads. Color-coded banks and matching displays simplify power management across multiple devices.

Technical Specifications

  • Digital LED load monitoring display
  • 20A circuit breaker per bank
  • Color-coded banks for easy identification

Applications

  • Power usage optimization
  • Load balancing management
  • Capacity planning
Detailed view of C13 outlets on PDU showing construction quality

Industrial-Grade C13 Outlet Design

Each C13 outlet is engineered for reliability and durability in demanding data center environments. The robust construction ensures secure connections and prevents accidental disconnections, while the standardized format maintains broad compatibility with IT equipment power cords.

Technical Specifications

  • IEC 60320 C13 outlet specification
  • Secure retention design
  • Enterprise-grade construction

Applications

  • Server power connection
  • Network switch deployment
  • IT equipment integration
Close-up view of multiple C13 outlets showing spacing and arrangement

High-Density C13 Outlet Configuration

The optimized outlet layout maximizes connection density while maintaining proper spacing for cable management. This design allows for efficient power distribution to multiple devices while preventing cord interference and maintaining proper airflow within the rack.

Technical Specifications

  • Optimized outlet spacing
  • Multiple outlet rows
  • Cable management compatibility

Applications

  • High-density server deployment
  • Scalable power distribution
  • Efficient space utilization
Close-up of PDU circuit breaker showing ON/OFF switch and labeling

Protected Circuit Control

Each bank features a dedicated 20A circuit breaker with clear ON/OFF indicators. The protected switch design prevents accidental shutoffs while providing quick access for intentional power cycling or emergency shutdowns. Clear labeling ensures proper bank identification during maintenance.

Technical Specifications

  • 20A circuit protection
  • Protected switch mechanism
  • Clear status indicators

Applications

  • Equipment protection
  • Maintenance procedures
  • Emergency power control
Detailed view of PDU digital amperage display with directional indicators

Advanced Load Monitoring Display

The digital load meter provides precise amperage readings with clear visibility. Dual-arrow indicators help identify the monitored bank, while the bright LED display ensures readability in any lighting condition. This real-time monitoring enables proactive power management and load optimization.

Technical Specifications

  • LED digital display
  • Real-time amperage monitoring
  • Clear bank identification

Applications

  • Power consumption tracking
  • Load balancing verification
  • Capacity management
Demonstration of PDU mounting system with button mount feature

Toolless Mounting System

The PDU features an innovative button-mount design for rapid deployment in standard server racks. Pre-installed mounting buttons and numbered rack unit indicators ensure precise positioning and alignment. This system enables quick installation and repositioning without additional tools.

Technical Specifications

  • Button-mount installation
  • Rack unit indicators
  • 0U mounting capability

Applications

  • Rapid rack deployment
  • Easy PDU repositioning
  • Space-efficient installation
Close-up of NEMA L6-30P locking power plug

Industrial-Grade Power Input

The NEMA L6-30P input connector delivers reliable 230V power with a secure locking mechanism. Gold-plated contacts ensure optimal conductivity and long-term durability. The 10-foot cord provides flexible installation options while maintaining proper power delivery.

Technical Specifications

  • NEMA L6-30P locking connector
  • Gold-plated contacts
  • 10-foot power cord

Applications

  • High-amperage power delivery
  • Secure power connection
  • Flexible installation
Layout of PDU installation kit components including mounting hardware and plug locks

Complete Installation Kit

Every PDU includes a comprehensive mounting and security kit. The package contains plug-lock inserts for both C13 and C19 outlets, mounting brackets, and all necessary hardware. This ensures a complete installation solution for secure and professional deployment.

Technical Specifications

  • C13/C19 plug-lock inserts
  • Mounting brackets included
  • Complete hardware set

Applications

  • Secure outlet retention
  • Professional installation
  • Comprehensive deployment
FAQ
The Tripp Lite PDUMV30HV2 is a 5800W, 230V single-phase PDU featuring 48 outlets (40 C13 and 8 C19) arranged in two separate load banks. It's a 0U vertical rack-mount unit measuring 70 inches in height, with a NEMA L6-30P input plug and a 10-foot power cord. Each load bank has 24 outlets with dedicated 20A circuit breakers and digital meters for real-time current monitoring.
The PDU features two separate load banks, each containing 24 outlets (20 C13 and 4 C19). Each bank has its own dedicated 20A circuit breaker and digital ammeter that displays real-time output current. This design allows users to maintain balanced loads and prevent circuit overloads. The outlets, breakers, and ammeters are color-coded and labeled for easy identification and monitoring.
The PDUMV30HV2 is designed for 0U vertical rack mounting and comes with pre-installed 9mm buttons and additional mounting hardware. It measures 70 inches (178 cm) in height, 2.2 inches in width, and 2.5 inches in depth, weighing approximately 12.35 pounds. The vertical design maximizes rack space efficiency by mounting in the rack's zero-U space.
This PDU includes multiple safety features: overload protection with 20A circuit breakers for each bank, special guards to prevent accidental breaker trips, included plug-lock inserts for C13 and C19 outlets to prevent accidental disconnections, and a ground screw for equipment requiring chassis ground. It's also RoHS compliant and includes comprehensive circuit monitoring capabilities.
The package includes the PDUMV30HV2 48-Outlet PDU, 48 plug-lock inserts (40 C13 and 8 C20), spare installation buttons (2.9mm/4.6mm), a ground screw, mounting hardware, and the owner's manual. All necessary components for installation and secure operation are provided in the box.
The PDUMV30HV2 operates at 208/240V with a power rating of 5800W and requires a 30A input current. It features a NEMA L6-30P input plug with a 10-foot cord for connection to a compatible AC power source, generator, or protected UPS. The unit distributes 230V AC output through its 48 outlets.
Yes, the PDUMV30HV2 is both TAA and RoHS compliant, making it suitable for government and environmentally conscious installations. It's manufactured in Taiwan and comes with a 2-year warranty from Tripp Lite by Eaton, meeting various regulatory and environmental standards.
The PDU provides 48 total outlets with a mix of 40 C13 and 8 C19 outlets, supporting various equipment power requirements. The C13 outlets are ideal for standard network devices, while the C19 outlets accommodate higher-power devices. All outlets include plug-lock inserts (C13 and C20) to secure power connections and prevent accidental disconnections.