Tripp Lite Isolator IS1000HGDV Isolation Transformer Dual-Voltage 115/230V 1000W Medical-Grade Isolation Transformer Tripp Lite Isolator IS1000HGDV Isoleringsomformere Dual-Spænding 115/230V 1000W Medicinsk-Grade Isolator omformer.
Tripp Lite Isolator IS1000HGDV Isolation Transformer Dual-Voltage 115/230V 1000W Medical-Grade Isolation Transformer Tripp Lite Isolator IS1000HGDV Isoleringsomformere Dual-Spænding 115/230V 1000W Medicinsk-Grade Isolator omformer.
Tripp Lite IS1000HGDV
- Free Shipping
- 1 År Garanti
- 30 dages returret
- Kulstofneutral.
Produktets nøglefunktioner
- Beskytter følsomt udstyr mod EMI/RFI lin støj og spædninger
- Kumulativ lækagestrøm mindre end 80 μA
- Slukker automatisk for alle udtag i tilfælde af overbelastning
- Tilbyder fuld isolering fra input AC-netspænding
- Ideel til brug i ethvert industrielt, netværks- eller medicinsk miljø
timer
minutter
Forsendelsesoplysninger
Tripp Lite
IS1000HGDV
IS1000HGDV Isolator® Series Dual-Voltage 115/230V 1000W 50/60Hz Medical-Grade™ Transformer med fuld CAN/ES/IEC/EN 60601-1 godkendelse er ideel til at beskytte følsomt elektronisk udstyr i patientplejeområder. Den kan konfigureres til enten step-up spænding, step-down spænding eller pass-through spændingsdrift. Sammen med linjeisolering og kontinuerlig EMI/RFI linjestøj filtrering, har dens overspændingsbeskyttelsesvurdering på 240 joules evnen til at undertrykke overskydende spænding for at forhindre det i at beskadige tilsluttet udstyr.
En intern lavimpedans isoleringstransformatorkomponent tilbyder 100% isolation fra indgangsmains AC-linjen. Faraday-skærmen reducerer den samlede lækstrøm af IS1000HGDV og tilsluttet udstyr til niveauer under 80 mikroampere, mens den fjerner forsyningsskift transients og harmoniske, der genereres af andre lokale belastninger og reducerer indvirkningen af forsynings- eller lynrelaterede overspændingsforhold.
Transformatorfiltrering giver kontinuerlig fællesmode støjafvisning uden slidbare dele. IS1000HGDV reducerer 6000V IEEE 587 Kategori A og B ringbølge- og kombinationsbølge testoverspændinger til kun 0.5V fællesmode.
Komponenter forbindes til otte C13 stikkontakter med sikringsoverbelastningsbeskyttelse og en lysende tænd/sluk kontakt. Den robuste enhedshus af metal leveres klar til placering i ethvert industrielt, medicinsk, kontor-, netværks- eller audio/video-miljø. Kræver et C14-til-C13 AC-inputkabel (sælges separat).
``` Let me know if you need anything else!Tripp Lite IS1000HGDV Product Summary
- Transformer with full CAN/ES/IEC/EN 60601-1 listing for patient care vicinities
- Offers line isolation, step-up and step-down capabilities, and continuous noise filtering
- Faraday shield offers 100% isolation from input AC line
- Cumulative leakage current less than 80 µA
- 1000W continuous capacity with 8 C13 outlets
- Selectable 115V/230V input/output voltage
- 240 joules of AC surge protection
Typical Applications
- Protect lab equipment in patient care vicinities where an isolated ground is essential for safe operation of sensitive electronics
- Prevent misdiagnosis due to artifacts and shadowing caused by EMI/RFI line noise in imaging and diagnostic centers
- Use a 120V device in a facility with 230V input (or a 230V device with 120V input)
- Lower the accumulative leakage current to levels required for UL 60601-1 compliance within patient care vicinities
Medical-Grade Transformer Isolates and Protects Valuable Equipment in Patient Care Vicinities
The IS1000HGDV Medical-Grade™ Transformer, part of Tripp Lite’s acclaimed Isolator® series, with full CAN/ES/IEC/EN 60601-1 listing is ideal for protecting sensitive electronics, including diagnostic and lab equipment, in patient care vicinities. UL 60601-1 compliance is required for isolation transformers within patient care vicinities to avoid hazardous conditions and provide an optimally safe environment for patients, staff and visitors.
High-Capacity, Dual-Voltage Unit Ensures Equipment Safety in Hazardous Conditions
At 1000 watts, the IS1000HGDV has more than enough capacity to handle a variety of essential devices. Selectable 115V/230V input/output voltage with step-up, step-down or pass-through operation is also suitable for a wide range of devices and facilities. A 240-joule surge protection rating suppresses excess voltage to prevent it from damaging connected equipment (the unit automatically shuts down all outlets in case of overload). Transformer filtering provides continuous common-mode EMI/RFI line noise rejection with no wearable parts. The IS1000HGDV reduces 6000V IEEE 587 Category A and B ring wave and combination wave test surges to only 0.5V common mode.
Faraday Shield Design Provides Superior Line Isolation
By isolating equipment from unpredictable and disruptive utility power, the IS1000HGDV eliminates the need for dedicated circuits or costly upgrades to your facility’s electrical system. With 100-percent isolation from the input mains AC line, the Faraday shield reduces the cumulative leakage current of the IS1000HGDV and connected equipment to levels less than 80 microamps. It also removes utility switching transients and harmonics generated by other on-site loads and reduces the impact of utility- or lightning-related surge conditions.
Equi-Potential Earth Connection
The IS1000HGDV has both a potential equalization bolt (POAG) and an earth ground lug connector, which can be used for connecting to equi-potential earthing equipment terminals. The transformer can then be connected to other medical instruments. The POAG connection complies with the Medical Safety Standard EN 60601-1. Use the equi-potential earth screw to connect to any equipment that requires equi-potential earth connection and does not have a POAG connection.
Ships Ready for Immediate Placement in Your Busy Environment
The rugged all-metal housing is designed to withstand frequent use in demanding industrial, medical, office, network and audio/video applications. Equipment plugs into eight C13 outlets with fuse overload protection. A lighted on/off switch controls current to all eight outlets. A C14-to-C13 input cord (sold separately) is required for connecting the transformer to AC power.
What’s in the Box
- IS1000HGDV Dual-Voltage Medical-Grade Isolation Transformer
- (2) Fuse Sets (115V and 230V Operation)
- Input/Output Cable Selector Data Sheet
- Owner's Manual
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |