Tripp Lite PDU15NETLX 2-Outlet PDU 1.4KW Single Phase Mini Switched 120V Outlets IPv4/IPv6 HTTPS SNMPv3 SSH NTP
Tripp Lite PDU15NETLX 2-Outlet PDU 1.4KW Single Phase Mini Switched 120V Outlets IPv4/IPv6 HTTPS SNMPv3 SSH NTP
Tripp Lite PDU15NETLX
- Free Shipping
- 1 År Garanti
- 30 dages returret
- Kulstofneutral.
Produktets nøglefunktioner
- Indbygget LX Platform grænseflade muliggør fuld fjernadgang 24/7 med e-mail-notifikationer
- 2 vekselstrømsstik NEMA 5-15R kan fjernstartes, låses eller slukkes
- NEMA 5-15P indgang med 6 ft. ledning tilslutter til mains strøm, generator eller UPS-system
- Monteres på væg, under bord eller i 0U af rackplads ved hjælp af de medfølgende beslag
- Ideel lavprisoption til småinstallationer, der kræver højst 2 stikkontakter
timer
minutter
Forsendelsesoplysninger
Tripp Lite
PDU15NETLX
Switched PDU giver avanceret netværkskontrol og fjernovervågning af strøm
Denne 0U PDU er en ideel lavpris-løsning til små netværkskonfigurationer, hvor der kun er brug for en eller to stik. Den har to NEMA 5-15R individuelt switchbare udtag, som kan kontrolleres fjernmæssigt for at tænde, slukke, genstarte eller låse strømmen til ikke-responderende enheder. Frontpanelets LED'er viser hver udtags tænd/sluk-status.
Indbygget LX Platform netværksinterface tilbyder 24/7 adgang
Det indbyggede Java-frie HTML5-baserede LX Platform netværksinterface muliggør fuld fjernadgang til PDU-statusovervågning og e-mail-notifikationer via sikker webbrowser, SNMP, telnet eller SSH. Det understøtter 10/100 Mbps auto-sensing for optimal kommunikation med et Ethernet-netværk. Valgfri EnviroSense2-moduler (sælges separat) giver en række miljøovervågningsmuligheder, herunder temperatur- og fugtighedsforhold. Automatiserede advarsler hjælper med at forhindre utilsigtede overbelastninger, strømtab og nedetid. Understøttede protokoller omfatter IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2c, SNMPv3, telnet, SSH, FTP, DHCP og NTP. DHCP/manuel konfiguration gør det muligt at tildele netværksindstillinger til kortet automatisk, hvilket reducerer behovet for manuel konfiguration.
Reducer serviceopkald med Auto Probe autonom enhedsstyring
Auto Probe-funktionen (firmware 15.5.2 og højere) tjekker forbindelsesstatus for enhver netværksenhed og foretager automatisk en eller flere brugerkonfigurerede handlinger, hvis enheden ikke reagerer; handlinger omfatter outlet genstart, indstilling af SNMP traps, SNMP OID sæt, og endda scriptudførelse, når den bruges sammen med Tripp Lite PowerAlert Network Shutdown Agent (PANSA).
Nem tilslutning til en AC-strømkilde
Et seks fod langt strømledning med NEMA 5-15P stik forbinder PDU15NETLX 0U PDU til en kompatibel AC-strømkilde, generator eller beskyttet UPS.
Fleksible installationsmuligheder
Den switchbare PDU monteres lodret i 0U rack-plads, på en væg eller under en disk ved hjælp af de medfølgende monteringsbeslag og brugersupplerede hardware. Dens halvbredde rack-montageformfaktor gør det muligt at placere den på en hylde eller desktop.
TAA-kompatibel til GSA schedule køb
PDU15NETLX er kompatibel med den føderale handelsaftale (TAA) for GSA schedule køb.
2-års garanti og miljømæssigt ansvarlig design
Den robuste metal PDU15NETLX leveres med en 2-års garanti. Den er fremstillet i overensstemmelse med strenge RoHS-specifikationer, hvilket afspejler Tripp Lites forpligtelse til miljøansvar.
Advanced Network Monitoring Capabilities
The PDU15NETLX gives IT personnel enhanced oversight of network power conditions with a built-in, Java-free HTML5-based LX Platform interface. It remotely monitors site power conditions and PDU load levels, and supports notification and logging of all major power events and user-specified alarm thresholds via email or SNMP traps. The PDU15NETLX provides 10/100 Mbps auto-sensing for optimal communication compatibility with a 10/100 Base-T network. When used with Tripp Lite’s optional EnviroSense2 (E2) sensor, the PDU15NETLX can also remotely monitor temperature/humidity conditions, plus up to four dry contact interfaces for alarm, security, and telecom devices. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
Individual Outlet Current Monitoring and Remote Outlet Control
The PDU15NETLX offers the ability to turn on, turn off, recycle, or lock out power to either of its outlets as well as locally and remotely monitor each outlet’s output power consumption. This allows you to more efficiently manage network power consumption and properly balance loads both remotely and on-site. If equipment needs to be rebooted on a Sunday—no problem! Simply log on from wherever you are and take care of business.
Digital Current Meter and Outlet LEDs
The PDU15NETLX is equipped with a digital LED ammeter that allows IT personnel to monitor each load bank’s current, each outlet’s current and the total load in real time. This meter helps ensure the PDU is used at maximum capacity with no danger of overload. Each outlet is provided with an LED that illuminates to confirm power on/off status.
Flexible Installation Options
Ideal for small-scale network configurations in data centers and computer rooms, the PDU15NETLX’s compact metal housing mounts vertically in 0U of rack space, on a wall or under a counter using the included hardware.
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is a manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosure cabinets, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 90 years of quality products and service, Tripp Lite is a brand you can trust.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |