Tripp Lite PDU3EVSR6G60A SWITCHED PDU 16.2KW 3-FASE 18-Outlet PDU overvåget Overbelastningsbeskyttelse
Tripp Lite PDU3EVSR6G60A SWITCHED PDU 16.2KW 3-FASE 18-Outlet PDU overvåget Overbelastningsbeskyttelse
Tripp Lite PDU3EVSR6G60A
- Free Shipping
- 1 År Garanti
- 30 dages returret
- Kulstofneutral.
Produktets nøglefunktioner
- 6 C13 og 12 C19 208V stikkontakter distribuerer AC strøm til tilsluttet udstyr
- Indbygget Java-fri HTML5-baseret LX Platform grænseflade giver dig 24/7 fjernadgang
- Fjernovervågning og kontrol af strøm reducerer besøg på stedet og vedligeholdelsesomkostninger
- 6 ft. ledning med IEC 309 60A Blå (3P+E) 3-faset indgang tilslutter til kompatibel AC-kilde
- Farvetouchscreen LCD viser nuværende niveauer, miljødata og netværksoplysninger
timer
minutter
Forsendelsesoplysninger
Tripp Lite
PDU3EVSR6G60A
3-fase PDU distribuerer, overvåger og styrer netværkskvalitetsstrøm
Anbefalet til datacentre, serverrum og høj-tætheds netværksklæder, giver denne switchede PDU avanceret netværkskontrol og fjernovervågning af strøm med mulighed for at tænde, slukke, genstarte eller låse strømmen til hver udgang. Du kan mere effektivt styre netværkets energiforbrug og fjernafbryde låste netværksgenstande uden at skulle besøge stedet. Reduktion af antallet af besøg på stedet kan hjælpe med at reducere omkostningerne ved datacenterets vedligeholdelse, hvilket dermed sænker 0U PDUs samlede ejeromkostninger.
18 udgange distribuerer AC-strøm til tilknyttede udstyr
I normal drift distribuerer 18 individuelt kontrollerbare udgange - seks C13 og 12 C19 - i seks særskilt sikrede belastningsbanker AC-strøm til rackudstyr. Hver 208V udgang ledsages af en LED, der lyser, når udgangen er aktiveret og klar til brug. Udgange og banker kan overvåges individuelt for at sikre korrekt belastningsbalance og forhindre nedetid. Plug-lock indsatsmanchetter er inkluderet for at forhindre, at tilsluttede kabler bliver utilsigtet løsnet.
Indbygget LX Platform netværksstyringskort Muliggør fjernadgang 24/7
Den Java-frie HTML5-baserede LX Platform netværksgrænseflade muliggør fuld fjernadgang til PDU-statusovervågning og e-mail-notifikationer via sikker webbrowser, SNMP, telnet eller SSH. Den understøtter 10/100/1000 Mbps auto-sensing for optimal kommunikation med et Ethernet-netværk. Valgfri EnviroSense2-moduler (sættes separat) giver en række miljøovervågningsmuligheder. Understøttede protokoller inkluderer IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP og NTP. 0U PDU'en kan modtage IP-adresseringsmetoder via DHCP-server (automatisk) eller statisk (manuelt).
Farvetouchscreen LCD viser vigtig data ved et kig
En nemt navigerbar farvetouchscreen LCD rapporterer netværksdata, indgangsstrømniveau pr. fase og udgangsstrøm pr. belastningsbank og pr. udgang med ±1% faktureringsgrad nøjagtighed. Den genererer også en unik QR-kode for at muliggøre læseadgang til 3-fase PDU'en via mobil enhed. Hvis der er tilsluttet et EnviroSense2-modul til PDU'en, viser LCD'en også dens status og miljødata, såsom temperatur og luftfugtighed.
Nem at installere lodret i en EIA-standard 19-tommer rack
Den 70-tommer 0U PDU monteres lodret ved hjælp af de forinstallerede værktøjsfri monteringsknapper eller de medfølgende beslag. Ekstra knapper medfølger også. Brug den inkluderede PDUMVROTATEBRKT-sæt til at installere Hubbell PDU med udgange vendt mod bagenden for bedre luftstrøm eller udstyrsadgang. Et seks fod langt kabel med Hubbell 50A CS8365C (3P+E) 3-fase indgang forbinder den switchede PDU til en kompatibel AC-strømkilde, generator eller beskyttet UPS.
TAA-overholdende til GSA-købsordrer
PDU3EVSR6G60A er overholdende med den føderale handelsaftale (TAA), hvilket gør det berettiget til GSA (General Services Administration) Schedule og andre føderale indkøbsaftaler.
2-års garanti
PDU3EVSR6G60A er dækket af en 2-års garanti, der sikrer pålidelighed og ydeevne.
HTML5-Based Interface Provides Advanced Network Monitoring Capabilities
Featuring a built-in, Java-free, HTML5-based LX Platform interface (the mobile-friendly PowerAlert ® Device Manager), the PDU3EVSR6G60A provides complete remote access for power monitoring and email notifications via a secure network or Web browser. Automated alerts help prevent accidental overloads, power loss and downtime. When used with an optional EnviroSense2 environmental sensor (sold separately), it can also perform temperature/humidity and dry contact monitoring, providing IT personnel with enhanced oversight of facility power and environmental conditions. As an added bonus, up to three EnviroSense2 modules can be daisy-chained together. The PDU3EVSR6G60A supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts can be configured to warn against potential overload, power loss and downtime. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration support provides the ability to have network settings automatically assigned or manually assigned via a permanent IP address
0U PDU Distributes, Monitors and Manages 3-Phase Power with No Java Required
Tripp Lite's PDU3EVSR6G60A 16.2kW 3-Phase Switched PDU is an efficient, cost-effective, next-generation power distribution solution with remote monitoring capabilities. It’s perfect for data centers, server rooms, network closets and any IT environment in need of network-grade power. Its 18 outlets (6 C13 and 12 C19) are split into six separately breakered banks, which can each be monitored both remotely and with the unit’s LCD. Additionally, this advanced PDU offers the ability to remotely turn on, turn off, reboot or lock out power to each individual outlet. Designed for users who prefer a Java-free interface, this advanced vertical PDU distributes 208V 3-phase output and is recommended for any IT or industrial application. Its 6 ft. cord with IEC 309 60A Blue (3P+E) plug connects to a compatible power source, generator or UPS.
Gives IT Personnel Enhanced Oversight of Network Power Conditions
The PDU3EVSR6G60A offers the ability to locally and remotely monitor each of its six outlet banks as well as the PDU’s total output. This helps ensure proper balance across the PDU and prevents overloads that can cause downtime.
Reduces the Cost of Data Center MaintenanceAdvanced remote monitoring and control capabilities lower the PDU3EVSR6G60A’s total cost of ownership by reducing the frequency of on-site visits.
Reduces the Cost of Data Center Maintenance
This 0U PDU mounts vertically in EIA-standard 19 in. 2-post and 4-post racks using the included toolless mounting buttons or rack-mounting brackets. Using the included PDUMVROTATEBRKT mounting accessory, you can install it with outlets facing either the front or rear, whichever direction offers better airflow or equipment access. Once the PDU is installed in your rack, included plug-lock insert sleeves prevent cables from becoming accidentally disconnected from their outlets.
Comes Backed by a 2-Year Warranty
The PDU3EVSR6G60A comes with a 2-year warranty. It’s manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite’s commitment to environmental responsibility.
TAA-Compliant for GSA Schedule Purchases
The PDU3EVSR6G60A is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is a leading manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosures, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 95 years of quality products and service, Tripp Lite is a brand you can trust.
Return Policy |
Time to Return |
Standard Return Policy |
We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details. |
Replacement Only Return Policy |
Replacement within 30 days of the delivery date. |
Manufacturer Only Return Policy |
Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer. |
Holiday Extended Return Policies |
Extended Holiday Return Policy.Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024. Extended Holiday Replacement-Only Return PolicyQualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024. |