تريند لايت PDU3EVSR1L1530 36 مخرج PDU، مُدار، مُبدل، تصنيف طاقة 8600 واط، ثلاثي الطور، شاشة LCD متعددة الألوان

Full-length view of Tripp Lite PDU3EVSR1L1530 showing vertical outlet arrangement-alternate-image1
Vertical view of PDU showing outlet arrangement and mounting design-alternate-image2
Side view of PDU showing construction and housing design-alternate-image3
Close-up of PDU mounting system and installation points-alternate-image4
Detail of PDU power input connection and cabling-alternate-image5
Close-up of PDU control panel and display interface-alternate-image6
Detail view of Bank 1 outlets and labeling-alternate-image7
Close-up of Bank 3 outlet arrangement-alternate-image8
Detail of Bank 2 power distribution section-alternate-image9
Close-up of PDU mounting button and interface-alternate-image10
Detail of NEMA L15-30P power input connector-alternate-image11
Installation accessories and documentation package-alternate-image12

تريند لايت PDU3EVSR1L1530 36 مخرج PDU، مُدار، مُبدل، تصنيف طاقة 8600 واط، ثلاثي الطور، شاشة LCD متعددة الألوان

Tripp Lite PDU3EVSR1L1530

$2,675.82 $3,995.78 وفر $1,319.96
الشريك المعتمد
علامة تجارية جديدة
التوفر: في المخزون ، جاهز للشحن .
  • Free Shipping
  • سنة واحدة الضمان
  • 30 يومًا للإرجاع
  • محايدة مناخيا للكربون

ميزات مفتاح المنتج

  • 30 C13 و 6 C19 منافذ 200-240V توزع الطاقة المتناوبة للمعدات المتصلة
  • واجهة شبكة قابلة لـ GbE توفر إمكانيات إدارة عن بعد محسنة
  • شاشة LCD باللمس بالألوان توفر مستويات الحالية ، البيانات البيئية ومعلومات الشبكة
  • يعزل ويفجر فقط مأخذ الذيار الحالي ، مما يحافظ على توصيلات الحمل الأخرى للبنك مع المزود بالطاقة
  • متوافق مع قانون اتفاقيات التجارة الفيدرالي (TAA) لعمليات الشراء على جدول GSA
$2,675.82
مجانية الإرجاع
توصيل مجاني
اطلب في المرة القادمة

ساعات

دقائق

أن يتم تسليمه في

معلومات الشحن

-
+
اتصل بنا الآن
888.267.9566
Minimize
Info
Info Page
Reviews Top
×

×
  • وصف
  • مواصفات التقنية
  • سياسة الاسترداد

Tripp Lite

PDU3EVSR1L1530

Tripp Lite PDU3EVSR1L1530: Advanced 3-Phase 36-Outlet Managed PDU with Switched Control for Enterprise Data Centers

The Tripp Lite PDU3EVSR1L1530 is a high-performance 8600W three-phase PDU featuring 36 individually controllable outlets, advanced network management capabilities, and innovative IsoBreaker™ technology. This 0U vertical rack-mounted power distribution unit combines sophisticated power monitoring, including THDv waveform capture, with remote outlet control through its built-in Gigabit Ethernet interface, making it ideal for modern data centers and enterprise environments.

Advanced Power Distribution and Management Features

This managed PDU delivers reliable power through 30 C13 and 6 C19 outlets, operating at 200-240V AC. Each outlet features LED indicators for status monitoring and can be individually controlled for remote power cycling. The unit's sophisticated PADM20 firmware enables comprehensive remote management, including customizable dashboard monitoring and automated device reboot capabilities through the Auto Probe feature.

IsoBreaker™ Technology for Enhanced Reliability

The PDU incorporates innovative IsoBreaker™ technology that maintains critical system uptime by isolating power surges to individual outlets rather than entire banks. This selective tripping mechanism ensures that unaffected equipment remains operational during overload conditions, significantly reducing the risk of widespread system downtime.

Key Feature: THDv waveform capture functionality provides precise 200ms snapshots of power quality, essential for critical installations in data centers, hospitals, and airports.

Network Management and Monitoring Capabilities

The integrated network management card supports GbE connectivity and features the latest PowerAlert® Device Manager (PADM20) firmware. Combined with PowerAlert Element Manager (PAEM) software, it provides comprehensive remote monitoring, configuration backup, and firmware management capabilities. The multi-color LCD touchscreen offers instant access to critical PDU data, including phase-specific metrics and QR code generation for mobile device access.

Technical Specifications and Installation

With a robust 8600W power rating and 24A input current capacity, this PDU is equipped with a NEMA L15-30P plug for reliable three-phase power connection. The 0U vertical form factor (70" x 2.2" x 3.1") optimizes rack space utilization, while the included mounting hardware ensures secure installation.

Package Contents and Warranty

  • PDU3EVSR1L1530 36-Outlets PDU
  • Configuration Cable
  • Rack-Mounting Hardware
  • 2 Spare Mounting Buttons
  • 2 Toothed Washers
  • 2 M4 Black Phillips Head Machine Screws
  • PDUMVROTATEBRKT Mounting Bracket Accessory
  • Owner's Manual

The PDU is backed by a 2-year limited warranty and is both TAA and RoHS compliant, demonstrating Tripp Lite's commitment to quality and environmental responsibility.

الميزات | لوحة توزيع الطاقة ثلاثية الطور تتيح توزيع، مراقبة وإدارة الطاقة من الدرجة الشبكيةموصى به لمراكز البيانات، مقدمي خدمات الشبكة والشركات الكبيرة، هذه اللوحة المدارة مع واجهة شبكة مدمجة توفر التحكم المتقدم في الشبكة والمراقبة عن بعد للطاقة مع القدرة على تشغيل، إيقاف، إعادة تشغيل أو قطع الطاقة عن كل منفذ. يمكنك إدارة استهلاك الطاقة للشبكة بشكل أكثر كفاءة، والحفاظ على توازن الحمل الصحيح وإعادة تشغيل العناصر المقفلة عن بعد دون الحاجة لزيارة الموقع. يمكن أن يساعد تقليل عدد الزيارات الميدانية في خفض تكلفة صيانة مركز البيانات، وبالتالي خفض التكلفة الإجمالية للملكية للوحة PDU ذات 0U.36 مخرجًا توزع الطاقة الكهربائية على المعدات المتصلةخلال التشغيل العادي، تقوم 36 مخرجًا قابلاً للتحكم بشكل فردي - 30 C13 وستة C19 - في ثلاثة أحمال بتوزيع الطاقة الكهربائية على معدات الرفوف. يأتي كل مخرج من 200-240 فولت مع LED يضيء عند تشغيل المخرج واستعداده للاستخدام. يمكن مراقبة المخرجات والأحمال بشكل فردي لضمان مستويات الحمل المناسبة وتوازن الحمل.تكنولوجيا IsoBreaker™ تساعد في الحفاظ على وقت التشغيل الحرج أثناء الأحمال الزائدةتكنولوجيا IsoBreaker الابتكارية تمنع الحاجة إلى إيقاف تشغيل عدة أجهزة عند حدوث زيادة في الطاقة. في حالة حدوث زيادة في الطاقة بسبب حمل زائد في مخرج فردي، فإن قاطع الدائرة في حجرة الحمل يقوم بقطع الطاقة عن هذا المخرج فقط بدلاً من الحجرة بأكملها. يساعد ذلك في الحفاظ على وقت تشغيل الخوادم والمعدات الحيوية الأخرى التي تستطيع البقاء على الإنترنت، متجنبًا توقف العمل المكلف.مراقبة الطاقة المتطورة تشمل التقاط شكل موجة THDvبالنسبة للتثبيتات التي تكون فيها قياسات تشوه جهد الدخل محددة للغاية، مثل مراكز البيانات، المستشفيات والمطارات، فإن ميزة التقاط شكل موجة THDv تحدد وتلتقط جودة جهد الدخل للوحة PDU من خلال أخذ لقطة شكل موجة لمدة 200 مللي ثانية يتم تنشيطها بناءً على معايير THDv. ستلتقط ميزة التقاط شكل موجة THDv 100 مللي ثانية قبل و100 مللي ثانية بعد معايير الزناد. يساعد ذلك في توفير قراءات دقيقة للدخل والتقارير بدقة عن ضجيج الخط لمساعدتك في تشخيص مشاكل الطاقة وتجنب التوقف المستقبلي.بطاقة إدارة الشبكة المدمجة القابلة لـ GbE تتيح الوصول عن بعد على مدار الساعةتوفر الواجهة الشبكية المدمجة مع أحدث إصدار من برنامج PowerAlert® Device Manager (PADM20) قدرات إدارة عن بعد محسّنة، بما في ذلك الرسوم البيانية القابلة للتخصيص على لوحة المعلومات لتناسب تفضيلات المستخدم. يشكل ترقية PADM20 وبرنامج PowerAlert Element Manager (PAEM) أداة قوية لتوسيع وظائف الصيانة في التثبيتات الكبيرة، بما في ذلك فحوصات تحديثات البرنامج الاحتياطي واستعادة تكوينات الأجهزة. تسمح ميزة Auto Probe في PADM20 للوحة PDU ذات الأحمال القابلة للتبديل بإعادة تشغيل الأجهزة تلقائيًا إذا تم اكتشاف فشل في الاتصال الشبكي. وهذا يحافظ على وقت التشغيل ويقلل من الوقت والتكاليف المرتبطة بالدعم في الموقع.شاشة LCD باللمس الملون تقدم بيانات هامة في لمحةتقدم شاشة LCD باللمس الملون سهلة الاستخدام تحليلاً مفصلاً لبيانات دخل/خرج PDU لكل مرحلة، لكل حجرة ولكل منفذ. كما توفر معلومات عن استهلاك الطاقة وذروة الطلب على الطاقة. يمكنها توليد رمز QR فريد للسماح بالوصول للقراءة فقط إلى PDU عبر الجهاز المحمول. إذا تم توصيل وحدة EnviroSense2 (تباع بشكل منفصل) بـ PDU، فإن الشاشة تعرض أيضًا حالتها وبيانات البيئة، مثل درجة الحرارة والرطوبة.

Return Policy

Time to Return

Standard Return Policy

We offer a hassle-free 30-day returns policy for domestic (US) orders, excluding non-refundable items. Refund or Replacement within 30 days of the delivery date. All products that fall under the Standard Return Policy qualify for our 30-Day Hassle-Free Returns. Please see the section above for more details.

Replacement Only Return Policy

Replacement within 30 days of the delivery date.

Manufacturer Only Return Policy

Covered by the manufacturer's warranty. Please refer to the terms and conditions for the manufacturer's warranty or contact the manufacturer.

Holiday Extended Return Policies

Extended Holiday Return Policy.

Qualifying purchases of products displaying the " Extended Holiday Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Refund or Replacement until January 31, 2024.


Extended Holiday Replacement-Only Return Policy

Qualifying purchases of products displaying the " Extended Holiday Replacement-Only Return Policy ", from November 1st, 2023 to December 25, 2023, are eligible for a Replacement until January 31, 2024.

Full-length view of Tripp Lite PDU3EVSR1L1530 showing vertical outlet arrangement

Full-Length Power Distribution Excellence

The vertical 0U PDU features an optimized layout of 36 outlets arranged for efficient power distribution. The sleek black design incorporates LED indicators for each outlet, providing instant visual status monitoring. Strategic placement of C13 and C19 outlets ensures compatibility with various enterprise equipment.

Technical Specifications

  • 36 total outlets in vertical configuration
  • LED status indicators per outlet
  • 0U form factor design

Applications

  • High-density rack power distribution
  • Enterprise data center deployment
  • Managed power distribution systems
Vertical view of PDU showing outlet arrangement and mounting design

Vertical Mounting Efficiency

The PDU's slim profile maximizes rack space utilization while providing comprehensive power distribution capabilities. The vertical design incorporates both C13 and C19 outlets with clear labeling and organized grouping for optimal cable management.

Technical Specifications

  • Space-saving vertical design
  • Organized outlet grouping
  • Clear outlet labeling system

Applications

  • Rack space optimization
  • Structured cabling implementation
  • Enterprise power management
Side view of PDU showing construction and housing design

Robust Construction and Durability

The PDU's metal housing ensures long-term reliability in demanding data center environments. The sturdy construction supports continuous operation while providing proper heat dissipation and structural integrity.

Technical Specifications

  • Metal housing construction
  • Heat-dissipating design
  • Industrial-grade durability

Applications

  • 24/7 operation environments
  • High-reliability installations
  • Mission-critical facilities
Close-up of PDU mounting system and installation points

Professional Mounting System

The PDU features a secure mounting system designed for reliable installation in standard server racks. The mounting points are strategically placed to ensure stability and proper weight distribution.

Technical Specifications

  • Secure mounting design
  • Standard rack compatibility
  • Balanced weight distribution

Applications

  • Professional rack installation
  • Secure equipment mounting
  • Data center deployment
Detail of PDU power input connection and cabling

Comprehensive Input Connection

Features a professional-grade power input system with NEMA L15-30P connector, ensuring reliable three-phase power delivery. The input section includes proper strain relief and robust construction for long-term reliability.

Technical Specifications

  • NEMA L15-30P input connector
  • Three-phase power support
  • Industrial-grade strain relief

Applications

  • Three-phase power distribution
  • High-capacity power delivery
  • Enterprise power management
Close-up of PDU control panel and display interface

Intelligent Control Interface

The advanced control panel features an intuitive LCD display and navigation buttons for local management. Multiple interface options support comprehensive remote monitoring and control capabilities.

Technical Specifications

  • LCD display interface
  • Multi-button navigation
  • Network management ports

Applications

  • Local power monitoring
  • Remote management access
  • System configuration
Detail view of Bank 1 outlets and labeling

Bank 1 Power Distribution

The first power bank features clearly labeled outlets with individual circuit protection. Organized numbering system facilitates easy identification and management of connected devices.

Technical Specifications

  • Individual outlet protection
  • Clear numerical labeling
  • Circuit status indicators

Applications

  • Structured power distribution
  • Equipment load management
  • Circuit protection implementation
Close-up of Bank 3 outlet arrangement

Bank 3 Power Organization

Bank 3 provides additional power distribution capabilities with clearly marked outlets and protection features. The organized layout supports efficient cable management and device connection.

Technical Specifications

  • Protected outlet array
  • Organized outlet grouping
  • Power status monitoring

Applications

  • Scalable power distribution
  • Multi-device power management
  • Load balancing implementation
Detail of Bank 2 power distribution section

Bank 2 Configuration

The second power bank delivers additional outlet capacity with integrated protection features. Clear labeling and organized layout facilitate proper power distribution and management.

Technical Specifications

  • Protected outlet design
  • Sequential numbering system
  • Status monitoring capabilities

Applications

  • Systematic power distribution
  • Device power management
  • Load distribution control
Close-up of PDU mounting button and interface

Secure Mounting Interface

Features a robust mounting button system for secure installation in rack environments. The design ensures stable positioning and reliable operation in various rack configurations.

Technical Specifications

  • Heavy-duty mounting system
  • Secure attachment design
  • Flexible positioning options

Applications

  • Secure rack mounting
  • Professional installation
  • Stable equipment positioning
Detail of NEMA L15-30P power input connector

Industrial-Grade Power Input

The NEMA L15-30P connector provides reliable three-phase power input with robust construction and gold-plated contacts for optimal conductivity and long-term reliability.

Technical Specifications

  • NEMA L15-30P specification
  • Gold-plated contacts
  • Heavy-duty construction

Applications

  • Three-phase power integration
  • High-capacity power delivery
  • Industrial power distribution
Installation accessories and documentation package

Complete Installation Kit

Includes comprehensive documentation, mounting hardware, and configuration accessories. The package provides everything needed for professional installation and setup of the PDU system.

Technical Specifications

  • Complete mounting hardware set
  • Configuration cable included
  • Multi-language documentation

Applications

  • Professional system setup
  • Rack integration projects
  • Enterprise deployment
أسئلة وأجوبة
The Tripp Lite PDU3EVSR1L1530 is a 3-phase switched PDU with 36 outlets (30 C13 and 6 C19), featuring 8600W power rating and advanced management capabilities. Key features include a multi-color LCD touchscreen, built-in GbE network interface, IsoBreaker™ technology for selective outlet protection, THDv waveform capture, and remote power monitoring/control. It supports PADM20 firmware for enhanced remote management and includes individual outlet control with LED indicators for each outlet.
This PDU has an 8600W power rating with 230V AC input voltage and 24A input current. It features a NEMA L15-30P plug type and provides output voltage ranging from 200V AC to 240V AC. The unit distributes power across three phases, making it ideal for high-power density applications in data centers and enterprise environments.
The PDU3EVSR1L1530 features 36 total outlets divided into: 30 IEC 60320 C13 outlets and 6 IEC 60320 C19 outlets. Each outlet is individually controllable and features an LED indicator that shows when the outlet is powered up and ready for use. The outlets are arranged in three load banks for proper load balancing.
This PDU is designed for 0U vertical rack mounting, with dimensions of 70" height, 2.2" width, and 3.1" depth. It weighs approximately 18.52 lb and comes with rack-mounting hardware including a PDUMVROTATEBRKT mounting bracket accessory. The black vertical form factor makes it ideal for efficient rack space utilization.
The PDU features comprehensive management capabilities including a built-in GbE network card, PADM20 firmware, and PAEM software support. It offers remote outlet switching, power monitoring per phase/bank/outlet, energy consumption tracking, and peak power demand monitoring. The color touchscreen LCD provides detailed analysis and can generate QR codes for mobile device access. It's also compatible with EnviroSense2 modules for environmental monitoring.
The PDU incorporates IsoBreaker™ technology for advanced protection, which selectively trips individual outlets during overloads instead of entire banks. It includes circuit breaker protection and overload protection features. This selective tripping helps maintain uptime for critical equipment by isolating power issues to specific outlets rather than affecting multiple devices.
The package includes the PDU3EVSR1L1530 unit, configuration cable, rack-mounting hardware, 2 spare mounting buttons, 2 toothed washers, 2 M4 black Phillips head machine screws, PDUMVROTATEBRKT mounting bracket accessory, and owner's manual. All necessary components for installation and configuration are provided.
The PDU3EVSR1L1530 comes with a 2-year limited warranty. It is TAA compliant and environmentally certified with RoHS compliance. The unit is designed for data center and server applications, meeting necessary standards for professional enterprise deployment.